Evidence map›Paper›PMID 40467609›Full record

ArticleScientific reports2025

Real-time assessment of PV-DSTATCOM for grid power quality enhancement using an indirect current control strategy.

Vinamra Kumar Govil, S M Tripathi, Kuldeep Sahay

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Vinamra Kumar GovilDr. A.P.J. Abdul Kalam Technical University, Lucknow, India. vinamragovil1985@gmail.com.
S M TripathiDepartment of Electrical Engineering, Power and Energy Research Centre, Kamla Nehru Institute of Technology, Sultanpur, India.
Kuldeep SahayDepartment of Electrical Engineering, Institute of Engineering and Technology, Lucknow, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents a real-time simulation of a photovoltaic-based distribution static compensator (PV-DSTATCOM) using the Typhoon HIL 604 simulator, demonstrating its effectiveness in reactive power compensation, harmonic mitigation, and active power injection. The system seamlessly transitions between pure DSTATCOM mode, operating during night-time or when PV generation is zero, and PV-DSTATCOM mode, where it injects PV power while enhancing the power quality. A voltage source converter (VSC) regulated by an indirect current control strategy ensures improved power quality at the point of common coupling (PCC). Real-time simulation results under both balanced and unbalanced PCC voltage conditions validate the ability of the PV-DSTATCOM to mitigate power quality disturbances. Notably, the PV-DSTATCOM effectively reduces total harmonic distortion (THD), maintaining levels between 3.03%-5.58% under balanced PCC voltage and 3.95%-5.93% under unbalanced PCC voltage conditions, generally adhering to or remaining near the acceptable limit of IEEE-519 standards across varying solar irradiance levels and non-linear load conditions. Additionally, it maintains a near-unity power factor operation at PCC and stabilizes the DC-link voltage at 900 V (± 5%), ensuring reliable operation.

Indexed as

Harmonic mitigationIndirect current control strategyMaximum power point trackingPower qualityPV-DSTATCOMReactive power compensationReal-time simulationTotal harmonic distortion (THD)

Identifiers

PMID40467609
PMCPMC12137738

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.