Evidence map›Paper›PMID 40464358›Full record

ArticleJournal of applied clinical medical physics2025

Impact of respiratory motion on dose distribution in SIB-SBRT for lung cancer.

Lingling Liu, Zhenle Fei, Jie Li, Jiong Shu, Jingyuan Shao, Jianguang Zhang, Xiangli Cui, Hongzhi Wang

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Lingling LiuUniversity of Science and Technology of China, Hefei, China.
Zhenle FeiDepartment of Oncology, The 901st Hospital of Joint Logistics Support Force of the Chinese People's Liberation Army, Hefei, China.
Jie LiUniversity of Science and Technology of China, Hefei, China.
Jiong ShuUniversity of Science and Technology of China, Hefei, China.
Jingyuan ShaoUniversity of Science and Technology of China, Hefei, China.
Jianguang ZhangDepartment of Oncology, Zibo Wanjie Hospital, Zibo, China.
Xiangli CuiHefei Cancer Hospital of CAS, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China.
Hongzhi WangUniversity of Science and Technology of China, Hefei, China.

Funding

Health Research Program of Anhui AHWJ2024Ab0178National Science Foundation of China 82202945Nature Science Research Project of Anhui Province 2208085MA13
6 · The paper itself

Abstract

purposeRespiratory motion is a major source of dose uncertainty in lung cancer radiotherapy. The dose distribution of simultaneous integrated boost-stereotactic body radiotherapy (SIB-SBRT) is inhomogeneous and is significantly impacted by respiratory motion for lung cancer. The effect of respiratory motion on SIB-SBRT was investigated with a four-dimensional (4D) dose calculation method.

methodsNineteen previously treated lung cancer patients were selected for this planning study. All patients underwent four-dimensional CT (4D-CT) scanning, and volumetric modulated arc therapy (VMAT) treatments were planned with internal target volume (ITV) and planning target volume (PTV). Dose distributions (3D-plan) were calculated on the average reconstruction of the 4D-CT. 4D dose distributions (4D-plan) were calculated to evaluate respiratory motion effects. These calculations were performed on the CT images of related respiratory phase with a respiration-correlated assignment of the 3D plan's monitor units to the respiratory phases of the 4D-CT. Subsequently, the accumulative 4D dose based on deformable registrations of the CT series was generated and compared to the 3D dose distribution. Dosimetric deviations in targets and organs at risk (OARs) were analyzed with dosimetric parameters, and correlations between dose deviations (ΔV

resultsWith deformable registrations, the median values of relative differences between 3D-plan and 4D-plan 0 were found to be from -6.6% to 12.1% for all targets dosimetric parameters, and from -4.2% to 1.4% for OAR parameters. It was also shown that PTV coverage dropped more significantly than that of ITV with respiratory motion. Strong correlations were observed between the ΔV

conclusionRespiratory motion effects during SIB-SBRT treatment resulted in non-negligible dose variability. Furthermore, with the correlation relationship and respiratory motion parameters, the dose coverage reduction of targets could be predicted.

Indexed as

Four-Dimensional Computed TomographyLung NeoplasmsRadiosurgeryRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedRespirationAgedFemaleHumansMaleMiddle AgedMovementOrgans at RiskRadiotherapy Dosage4D dose calculationfour‐dimensional CTlung neoplasmsrespiratory motionSIB‐SBRT

Identifiers

PMID40464358
PMCPMC12256666

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.