Evidence map›Paper›PMID 40463631›Full record

ArticleFrontiers in cardiovascular medicine2025

Pulsed electric field ablation process-a study of the effect of different shapes (materials) of metal stents on the ablation effect.

Zhen Wang, Ming Liang, Jingyang Sun, Jie Zhang, Yunhao Li, Fengqi Xuan, Yaling Han

Abstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zhen WangCollege of Medicine and Biological Information Engineering, Northeastern University, Shenyang, China.
Ming LiangDepartment of Cardiology, General Hospital of Northern Theater Command, Shenyang, China.
Jingyang SunDepartment of Cardiology, General Hospital of Northern Theater Command, Shenyang, China.
Jie ZhangDepartment of Cardiology, General Hospital of Northern Theater Command, Shenyang, China.
Yunhao LiDepartment of Cardiology, General Hospital of Northern Theater Command, Shenyang, China.
Fengqi XuanDepartment of Cardiology, Tianjin Chest Hospital, Tianjin, China.
Yaling HanDepartment of Cardiology, General Hospital of Northern Theater Command, Shenyang, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Arrhythmias are a common group of cardiovascular diseases, and in recent years, pulsed electric field ablation technology has made great progress in the treatment of arrhythmias. However, the effect of different materials and shapes of cardiac stents on the ablation effect at the target site during epicardial ablation has not been effectively studied. Methods: The ablation targeting position was modeled and simplified, the ablation catheter and cardiac stent were restored in real size, and the ablation region was modeled in three dimensions using a computer. Multi-model cardiac stents were established and different materials were added to different stents, and the ablation region was effectively evaluated with a field strength of 1,000 V/cm as the contour. Results: The ablative electric field was present only at the ablation targeting site. In the computational simulation, the effective ablation width caused by the simplified metal stent was not significantly different from that of the real stent (the maximum difference in ablation width was 0.34 mm). The variation of the effective ablation area caused by different metals was small (for example, the ablation catheter was 0.5 mm away from the metal stent, and the width of the effective ablation area ranged from 9.79 mm to 10.13 mm). The maximum temperature change at the targeting site caused by the simplified stent of the scaffold was small (the maximum temperature after ablation was 43.88°C, and the maximum temperature after ablation of the real scaffold was 45.19°C). Conclusion: The simulation results show that the width of the targeted ablation area does not change greatly due to the shape and material of the metal stent, and the simplified metal stent model can effectively predict the effective ablation area. The metal stent has a certain warming effect on the ablation area, and the warming phenomenon of the real stent is more intense than that of the simplified stent, but this temperature change does not cause thermal damage to the targeting site.

Indexed as

arrhythmiacomputer simulationcoronary arterymetallic stentspulsed electric field ablationregion of ablation

Identifiers

PMID40463631
PMCPMC12131867

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.