Evidence map›Paper›PMID 40463354›Full record

ArticleJournal of rehabilitation and assistive technologies engineering

Design, development, and evaluation of a pneumatically actuated soft wearable robotic elbow exoskeleton for reducing muscle activity and perceived workload.

Eshwara Prasad Sridhar, Veysel Erel, Aida Nasirian, Muthu B J Wijesundara, Mahmudur Rahman

Abstract read
In one paragraph

Article in Journal of rehabilitation and assistive technologies engineering. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Eshwara Prasad SridharIndustrial, Manufacturing, and Systems Engineering Department, The University of Texas at Arlington, Arlington, TX, USA.ORCID https://orcid.org/0009-0004-4942-1815
Veysel ErelBiomedical Technologies Division, The University of Texas at Arlington Research Institute, Fort Worth, TX, USA.ORCID https://orcid.org/0000-0001-6324-8001
Aida NasirianBiomedical Technologies Division, The University of Texas at Arlington Research Institute, Fort Worth, TX, USA.
Muthu B J WijesundaraBiomedical Technologies Division, The University of Texas at Arlington Research Institute, Fort Worth, TX, USA.ORCID https://orcid.org/0000-0002-9755-1137
Mahmudur RahmanIndustrial, Manufacturing, and Systems Engineering Department, The University of Texas at Arlington, Arlington, TX, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: To reduce muscle strain and enhance user comfort, a Pneumatically Actuated Soft Wearable Robotic Elbow Exoskeleton was developed. The design integrates human joint mechanics with a single-piece pneumatic structure for optimal assistance and reduced complexity. Methods: Nineteen participants performed tasks under "Support On" and "Support Off" conditions to evaluate their effectiveness and feasibility. Muscle activity was measured using Surface Electromyography, while torque output and inflation times were assessed to gauge mechanical performance. Results: The Soft Wearable Robotic Elbow Exoskeleton reduced muscle activity in the biceps by 22.36% and in the triceps by 18.19% at 18 PSI (Pounds per Square Inch). Torque tests revealed a maximum output of 4.39 Nm at 21 PSI. Inflation time tests showed that the exoskeleton could reach total inflation in as little as 0.22 seconds in high mode at 25 PSI, demonstrating the ability to achieve rapid actuation speed and efficiency. Conclusions: These results indicate that the Soft Wearable Robotic Elbow Exoskeleton significantly reduces muscle activation, which may help mitigate the risk of work-related musculoskeletal disorders. By providing effective assistance during repetitive tasks, the exoskeleton enhances both mechanical performance and user comfort.

Indexed as

assistive technologybiomechanical testing/ analysiselectromyography (EMG)human factorshuman subject trialspneumatic exoskeletonwork-related musculoskeletal disorders (WMSD)

Identifiers

PMID40463354
PMCPMC12130663

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.