ArticleAnalytical and bioanalytical chemistry2025
Comparison of the quantification performance of thermal desorption GC-IMS and GC-MS in VOC analysis.
Article in Analytical and bioanalytical chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Interpol review of forensic drug chemistry, 2022-2025.Forensic science international. Synergy · 2026Review
- A novel substrate for CYP3A4 phenotyping: in vitro biotransformation of hubamine into butanone.Analytical and bioanalytical chemistry · 2026Article
- Analysis of the Effect of Autoclaving on the Flavor of Fresh Ginseng Using Electronic Nose, HS-GC-IMS, and HS-SPME-GC-MS.Foods (Basel, Switzerland) · 2026Article
- Analytical Challenges and Strategies for Compound Identification Using Gas Chromatography-Ion Mobility Spectrometry.Analytical chemistry · 2026Article
- A scalable PDMS extraction method for profiling fungal volatile compounds.Fungal biology and biotechnology · 2026Article
- Disentangling the roles of age and insect colonization in the temporal succession of VOC profiles in rat decomposition.Analytical and bioanalytical chemistry · 2026Article
- Genetic Algorithm-Driven Optimization of Mixed-Strain Fermentation for Improving the Physicochemical, Antioxidant, and Sensory Properties of Wampee (Foods (Basel, Switzerland) · 2025Article
- Simultaneous determination of 101 volatile organic compounds released from plastic runway tracks based on the environmental chamber-canister sampling-three-stage cold trap preconcentration-gas chromatography-mass spectrometry/flame ionization detection method.Frontiers in chemistry · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Accurate and reproducible quantification of volatile organic compounds (VOCs) is essential in environmental monitoring, clinical diagnostics, and quality control. Thermal desorption gas chromatography (TD-GC) is widely used for VOC analysis, often coupled with mass spectrometry (MS) for reliable identification. Ion mobility spectrometry (IMS) has gained attention for its high sensitivity and rapid detection. While GC-IMS and GC-MS are well established, TD-GC coupled to both IMS and MS has not been systematically investigated. This study presents a comprehensive assessment of a TD-GC-MS-IMS system, combining the strengths of both detectors. A mobile flow- and temperature-controlled sampling unit for TD tubes was developed for standardized applications, designed to introduce both gaseous and liquid samples. The long-term stability of TD-GC-IMS was assessed over 16 months with 156 measurement days using ketones. Relative standard deviations for signal intensities ranged from 3% to 13%, retention time deviations from 0.10% to 0.22%, and drift time deviations from 0.49% to 0.51%. Comparative evaluation showed IMS was approximately ten times more sensitive than MS, achieving limits of detections in the picogram/tube range. In contrast, MS exhibited a broader linear range, maintaining linearity over three orders of magnitude (up to 1000 ng/tube), while IMS retained linearity for one order of magnitude (e.g., 0.1 to 1 ng/tube for pentanal) before transitioning into a logarithmic response. To improve IMS quantification, a linearization strategy extended the calibration range from one to two orders of magnitude. These findings establish a standardized TD-GC-MS-IMS framework, improving reproducibility and comparability for clinical, environmental, and industrial VOC analysis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.