Evidence map›Paper›PMID 40457875›Full record

ArticleTrends in hearing

Comparison of Deep Learning Models for Objective Auditory Brainstem Response Detection: A Multicenter Validation Study.

Yin Liu, Lingjie Xiang, Qiang Li, Kangkang Li, Yihan Yang, Tiantian Wang, Yuting Qin, Xinxing Fu, Yu Zhao, Chenqiang Gao

Abstract readMulticenter StudyValidation StudyComparative Study
In one paragraph

Article in Trends in hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Yin LiuSchool of Communications and Information Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China.
Lingjie XiangSchool of Communications and Information Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China.
Qiang LiSchool of Communications and Information Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China.
Kangkang LiTianyue Xinchuang Information Technology Corporation, Beijing, China.
Yihan YangDepartment of Otolaryngology Head and Neck Surgery, Peking University First Hospital, Beijing, China.
Tiantian WangSchool of Communications and Information Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China.
Yuting QinSchool of Communications and Information Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China.
Xinxing FuBeijing Institute of Otolaryngology, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
Yu ZhaoSchool of Communications and Information Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China.
Chenqiang GaoSchool of Communications and Information Engineering, Chongqing University of Posts and Telecommunications, Chongqing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Auditory brainstem response (ABR) interpretation in clinical practice often relies on visual inspection by audiologists, which is prone to inter-practitioner variability. While deep learning (DL) algorithms have shown promise in objectifying ABR detection in controlled settings, their applicability to real-world clinical data is hindered by small datasets and insufficient heterogeneity. This study evaluates the generalizability of nine DL models for ABR detection using large, multicenter datasets. The primary dataset analyzed, Clinical Dataset I, comprises 128,123 labeled ABRs from 13,813 participants across a wide range of ages and hearing levels, and was divided into a training set (90%) and a held-out test set (10%). The models included convolutional neural networks (CNNs; AlexNet, VGG, ResNet), transformer-based architectures (Transformer, Patch Time Series Transformer [PatchTST], Differential Transformer, and Differential PatchTST), and hybrid CNN-transformer models (ResTransformer, ResPatchTST). Performance was assessed on the held-out test set and four external datasets (Clinical II, Southampton, PhysioNet, Mendeley) using accuracy and area under the receiver operating characteristic curve (AUC). ResPatchTST achieved the highest performance on the held-out test set (accuracy: 91.90%, AUC: 0.976). Transformer-based models, particularly PatchTST, showed superior generalization to external datasets, maintaining robust accuracy across diverse clinical settings. Additional experiments highlighted the critical role of dataset size and diversity in enhancing model robustness. We also observed that incorporating acquisition parameters and demographic features as auxiliary inputs yielded performance gains in cross-center generalization. These findings underscore the potential of DL models-especially transformer-based architectures-for accurate and generalizable ABR detection, and highlight the necessity of large, diverse datasets in developing clinically reliable systems.

Indexed as

Deep LearningEvoked Potentials, Auditory, Brain StemHearingHearing TestsAdolescentAdultAgedChildChild, PreschoolDatasets as TopicFemaleHumansMaleMiddle AgedNeural Networks, ComputerPredictive Value of Testsauditory brainstem responsedeep learninggeneralizabilitymulticenter validationobjective detection

Identifiers

PMID40457875
PMCPMC12134522

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.