Evidence map›Paper›PMID 40454658›Full record

ArticleInternational journal for numerical methods in biomedical engineering2025

Translation of Animal Study to Human: In Silico Based Development of Implantable Pulmonary Artery Pressure Sensor.

Leonid Goubergrits, Pavlo Yevtushenko, Adriano Schlief, Jan Romberg, Titus Kuehne, Andreas Arndt, Jan Bruening

Abstract read
In one paragraph

Article in International journal for numerical methods in biomedical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Leonid GoubergritsInstitute of Computer-Assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charité, Berlin, Germany.ORCID https://orcid.org/0000-0002-1961-3179
Pavlo YevtushenkoInstitute of Computer-Assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charité, Berlin, Germany.
Adriano SchliefInstitute of Computer-Assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charité, Berlin, Germany.
Jan RombergBiotronik, Berlin, Germany.
Titus KuehneInstitute of Computer-Assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charité, Berlin, Germany.
Andreas ArndtBiotronik, Berlin, Germany.
Jan BrueningInstitute of Computer-Assisted Cardiovascular Medicine, Deutsches Herzzentrum der Charité, Berlin, Germany.

Funding

European Commission 101017578
6 · The paper itself

Abstract

Implantable pulmonary artery pressure sensors (PAPS) might impose a flow-induced risk of thrombus formation in the pulmonary artery (PA). To assess this risk, an in silico study-enhanced animal study with 20 sensors implanted in 10 pigs had previously been conducted. In the in silico study, PAPS were virtually implanted mimicking real implantations, based upon data acquired by CT. This animal in silico study investigated changes in hemodynamics caused by PAPS using image-based computational fluid dynamics (CFD). However, porcine and human PA differ significantly in geometry and hemodynamics. To investigate the transferability of animal in silico study findings toward human conditions, we propose a parallel in silico human study. Based on a similarity analysis (L1 norm for 8 geometric features) human PA geometries with the least difference to 10 porcine PA were selected. PAPS were virtually implanted in human PA as close as possible, mimicking the implantation configuration of the animal study. Finally, a numerical flow analysis of the hemodynamic changes due to PAPS implantation was done. Comparing human and porcine PA, we found significantly larger left and right PA diameters in humans, whereas no differences were found for main PA diameters and bifurcation angle. Comparing hemodynamic boundary conditions, we found a significantly smaller heart rate and a significantly higher peak systolic main PA flow rate in humans, whereas no significant differences for cardiac output were found. The human in silico PAPS study found no relevant changes in hemodynamics increasing the risk of thrombus formation after sensor implantation. This is also valid for PAPS that were non-optimally implanted. Thus, despite differences between species, findings of the in silico animal study were confirmed by the human in silico study.

Indexed as

Blood PressureBlood Pressure DeterminationHemodynamic MonitoringProstheses and ImplantsPulmonary ArteryTranslational Research, BiomedicalAnimalsComputer SimulationHumansModels, AnimalRiskSwineThrombosisanimal trialcomputational fluid dynamicspressure sensorpulmonary arterythrombus formation

Identifiers

PMID40454658
PMCPMC12128572

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked