Reproducibility and accuracy of corneal curvature measurements in patients with and without dry eye: a device-based study.

Xuemei Zhang, Kunhong Xiao, Taichen Lai, Rongyong Zhang, Mengxue Huang, Ying Xue, Li Li, Huiying Rao

Abstract read
In one paragraph

Article in Frontiers in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xuemei Zhang *Shengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, China.
Kunhong Xiao *Department of Optometry, School of Medical Technology and Engineering, Fujian Medical University, Fuzhou, China.
Taichen LaiShengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, China.
Rongyong ZhangDepartment of Ophthalmology, Fuzhou University Affiliated Provincial Hospital, Fuzhou University, Fuzhou, China.
Mengxue HuangDepartment of Ophthalmology, Fuzhou University Affiliated Provincial Hospital, Fuzhou University, Fuzhou, China.
Ying XueShengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, China.
Li LiShengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, China.
Huiying RaoShengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To evaluate the reproducibility and accuracy of corneal curvature measurements using five different devices in patients with and without dry eye, and to identify the most reliable device for clinical use in dry eye patients. Methods: This study included 68 eyes from dry eye patients (dry eye group) and 48 eyes from non- dry eye patients (non- dry eye group). Corneal curvature was measured with five devices: Corneal topography, ARK-1a, IOL Master 700, OPD-Scan III, Pentacam. A total of 580 examination reports were collected. Reproducibility was assessed using intraclass correlation coefficients (ICCs), and accuracy was evaluated using Bland-Altman analyses. Differences between devices were examined through paired-sample Results: In both groups, the ICCs for ARK-1a, IOL Master 700, OPD-Scan III, and Pentacam were all > 0.9, indicating high reproducibility. Compared to the dry eye group, the non- dry eye group generally had narrower confidence intervals. Bland-Altman analyses showed that the 95% limits of agreement (LOA) were wider in the dry eye group, indicating greater variability. However, the LOA of IOL Master 700 and OPD-Scan III remained below 1.0 in the dry eye group, suggesting higher reliability and potential clinical advantages. Conclusion: Dry eye significantly affects the reliability of corneal curvature measurements, especially with optical reflection-based devices. Corneal topography and Pentacam are more sensitive to tear film abnormalities, while the IOL Master 700 and OPD-Scan III show more consistent results, making them preferable for clinical practice, such as clinical applications including refractive surgery planning, contact lens fitting, and preoperative cataract assessment.

Indexed as

corneal curvaturedry eyemultiple devicereproducibilitytear film