Evidence map›Paper›PMID 40453488›Full record

ArticleIEEE transactions on nuclear science2025

TlBr Films for Direct Digital Radiography.

M S Squillante, M J Breen, J F Christian, A Kargar, Y Ogorodnik, F Robertson, V Nagarkar, M R Squillante, L Cirignano, O Maksimov and 3 more

Abstract read
In one paragraph

Article in IEEE transactions on nuclear science, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

M S SquillanteRadiation Monitoring Devices, Inc., 44 Hunt St, Watertown, MA, 02472, USA.
M J BreenRadiation Monitoring Devices, Inc., 44 Hunt St, Watertown, MA, 02472, USA.
J F ChristianRadiation Monitoring Devices, Inc., 44 Hunt St, Watertown, MA, 02472, USA.
A KargarRadiation Monitoring Devices, Inc., 44 Hunt St, Watertown, MA, 02472, USA.
Y OgorodnikRadiation Monitoring Devices, Inc., 44 Hunt St, Watertown, MA, 02472, USA.
F RobertsonRadiation Monitoring Devices, Inc., 44 Hunt St, Watertown, MA, 02472, USA.
V NagarkarRadiation Monitoring Devices, Inc., 44 Hunt St, Watertown, MA, 02472, USA.
M R SquillanteRadiation Monitoring Devices, Inc., 44 Hunt St, Watertown, MA, 02472, USA.
L CirignanoRadiation Monitoring Devices, Inc., 44 Hunt St, Watertown, MA, 02472, USA.
O MaksimovRadiation Monitoring Devices, Inc., Watertown, MA, USA.
H KimRadiation Monitoring Devices, Inc., Watertown, MA, USA.
K KarimKA Imaging, Inc., 560 Parkside Dr, Unit 3, Waterloo, Ontario, Canada.
C ScottKA Imaging, Inc., 560 Parkside Dr, Unit 3, Waterloo, Ontario, Canada.

Funding

Semiconductor detector for low-dose, high-resolution dental DR imagingR44DE032290 · NIDCR · RADIATION MONITORING DEVICES, INC. · PI CHRISTIAN, JAMES F · 2022 to 2024
$2.0M
Innovative High Resolution Dental X-ray ImagerR44DE026373 · NIDCR · RADIATION MONITORING DEVICES, INC. · PI SQUILLANTE, MICHAEL R. · 2019 to 2020
$954k
NIDCR NIH HHS R44 DE026373NIDCR NIH HHS R44 DE032290
6 · The paper itself

Abstract

The detector that converts X-ray intensity into a digitized electronic signal, processed into an image, often limits the performance of modern X-ray imaging systems, whether for medical, research, or industrial applications. Digital radiography uses the following two types of detectors: indirect detectors, where a scintillating film converts X-ray into an optical signal read by an optical detector, and direct detectors using semiconductors. Semiconductor X-ray detector technology typically uses a silicon wafer, an amorphous Se (aSe) film, or a relatively thin CdZnTe crystal bump bonded to a readout platform. Although the use of aSe and CdZnTe improves the attenuation coefficient beyond that of silicon, a further increase in performance is highly desirable for improved imaging off higher energy X-rays (greater than 20 keV). This paper presents results on thallium bromide (TlBr) films coupled to a read-out integrated circuit (ROIC). Thallium Bromide, an attractive material for hard X-ray imaging due to its high atomic number and high density, achieves an image resolution of 20 μm as a 1 cm

Indexed as

hard X-ray imagingintegrating ROICROICsemiconductor X-ray detectorThallium bromide

Identifiers

PMID40453488
PMCPMC12121991

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.