Evidence map›Paper›PMID 40453425›Full record

ArticleFrontiers in surgery2025

Three-dimensional visualization measurement and analysis of human hepatic pedicle based on Laennec's capsule.

Zhiyu Lin, Xin Xia, Yuchuan Luo, Huan Lei, Hongyin Liang, Hui Zhang, Zhiwei Jiang, Tao Wang

Abstract read
In one paragraph

Article in Frontiers in surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Zhiyu LinDepartment of General Surgery (Hepatopancreatobiliary Surgery), The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China.
Xin XiaDepartment of General Surgery (Hepatopancreatobiliary Surgery), The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China.
Yuchuan LuoDepartment of General Surgery, The General Hospital of Western Theater Command, Chengdu, Sichuan, China.
Huan LeiDepartment of General Surgery, The General Hospital of Western Theater Command, Chengdu, Sichuan, China.
Hongyin LiangDepartment of General Surgery, The General Hospital of Western Theater Command, Chengdu, Sichuan, China.
Hui ZhangDepartment of General Surgery, The General Hospital of Western Theater Command, Chengdu, Sichuan, China.
Zhiwei JiangDepartment of General Surgery, The General Hospital of Western Theater Command, Chengdu, Sichuan, China.
Tao WangDepartment of General Surgery (Hepatopancreatobiliary Surgery), The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Laennec's capsule serves as a crucial anatomical landmark in liver surgery, yet imaging-based morphometric studies of this fibrous membrane remain limited. This study introduces a novel 3D reconstruction technique to visualize and measure the hepatic pedicle via Laennec's capsule, with validation focused on the left portal branch and development of a 3D-printed model for surgical planning. Methods: 30 patients undergoing left hemihepatectomy were recruited to validate the accuracy of a Laennec's capsule-based 3D reconstruction system (Hisense CAS). Preoperative measurements of the left branch length, diameter, and the angle between the main trunk and the hepatic pedicle were compared with intraoperative findings. Additionally, 100 adults without hilar lesions underwent 3D reconstruction for comprehensive morphological classification and statistical analysis of the hepatic pedicle trunk and main branches. Results: No statistically significant differences emerged between the 3D reconstruction data and intraoperative measurements, confirming the method's accuracy. Four distinct branching patterns were identified, with Type I accounting for 88% of cases. At the first hepatic hilum, the mean outer diameter of the hepatic pedicle was 24.10 ± 6.16 mm. The left and right main branches demonstrated considerable variability in length (20.59 ± 6.38 mm vs. 21.99 ± 7.97 mm) and outer diameter (18.04 ± 4.48 mm vs. 21.18 ± 4.23 mm). The angle between the left and right main branches was 140.81 ± 16.72°. Furthermore, a 3D-printed liver model was developed to aid in surgical planning and education. Conclusions: Three-dimensional reconstruction based on Laennec's capsule accurately reflects hepatic pedicle anatomy and its variations. The predominance of Type I branching underscores the need for precise classification during liver surgery. This approach provides valuable morphological data for individualized surgical planning, improves intraoperative safety, and sets the stage for further research integrating alternative imaging modalities and larger patient cohorts.

Indexed as

3D printinghepatic pedicleLaennec's capsulesegmenationthree dimensional reconstruction

Identifiers

PMID40453425
PMCPMC12122467

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.