Evidence map›Paper›PMID 40453207›Full record

Trial reportDrug design, development and therapy2025

Comparison of the Dural Puncture Epidural and Conventional Epidural Analgesia Maintained Using Programmed Epidural Boluses for Labor Analgesia.

Xiaofei Mo, Jie Yu, Zhimin Qin, Junyi Ma, Yueyue Chen, Xi Chen

Abstract readComparative StudyRandomized Controlled Trial
In one paragraph

Trial report in Drug design, development and therapy, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Trial
  2. Trial
  3. ECDrug design, development and therapy · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xiaofei Mo *Department of Anesthesiology, Guangzhou Medical University Affiliated Women and Children's Medical Center, Guangzhou, People's Republic of China.ORCID 0000-0001-6635-2680
Jie Yu *Department of Anesthesiology, Guangzhou Medical University Affiliated Women and Children's Medical Center, Guangzhou, People's Republic of China.ORCID 0009-0008-2553-2325
Zhimin QinDepartment of Anesthesiology, Guangzhou Medical University Affiliated Women and Children's Medical Center, Guangzhou, People's Republic of China.
Junyi MaDepartment of Anesthesiology, Guangzhou Medical University Affiliated Women and Children's Medical Center, Guangzhou, People's Republic of China.
Yueyue ChenDepartment of Anesthesiology, Guangzhou Medical University Affiliated Women and Children's Medical Center, Guangzhou, People's Republic of China.
Xi ChenDepartment of Anesthesiology, Guangzhou Medical University Affiliated Women and Children's Medical Center, Guangzhou, People's Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Research indicates that the dural puncture epidural (DPE) technique offers quicker analgesia onset compared to the conventional epidural (EP) technique. Programmed intermittent epidural bolus (PIEB) is superior to continuous epidural infusion (CEI) for maintaining labor analgesia, providing better pain relief and less motor block. Few studies have explored if combining DPE with the PIEB offers additional benefits in analgesia onset, maintenance, local anesthetic consumption, and side effects compared to DPE with EP. We hypothesized that DPE, when combined with PIEB, not only speeds up analgesia onset but also improves neuraxial analgesia maintenance over EP. Patients and Methods: A total of 126 term nulliparous women with singleton pregnancies with a VAS pain score >50 mm and cervical dilation <5 cm were randomized to receive EP+PIEB or DPE+PIEB for labor analgesia, initiated with 15 mL of 0.0625% ropivacaine with 0.4 µg/mL of sufentanil using the EP or DPE technique (using 25-gauge Whitacre needle) technique and both maintained with the same solution for PIEB (fixed volume 10 mL, intervals 45 minutes, lockout interval 15 minutes) with labor analgesia. The primary outcome was time to achieving adequate analgesia, defined as a VAS pain score ≤30 mm. Secondary outcomes included pain scores, motor blockade, obstetric and neonatal outcomes, and satisfaction with analgesia. Results: Adequate analgesia was achieved faster in the DPE+PIEB group than in the EP+PIEB group (hazard ratio 2.409; 95% CI 1.670 to 3.474, Conclusion: DPE with PIEB accelerated onset time but did not improve maintenance of neuraxial labor analgesia over DPE with EP.

Indexed as

Analgesia, EpiduralAnalgesia, ObstetricalAnesthetics, LocalLabor PainSufentanilAdultFemaleHumansPain MeasurementPregnancyRopivacaineAnesthetics, LocalRopivacaineSufentanilanalgesiaepidurallabor painspinal puncture

Identifiers

PMID40453207
PMCPMC12125473

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.