ArticleBMJ health & care informatics2025
GenECG: a synthetic image-based ECG dataset to augment artificial intelligence-enhanced algorithm development.
Article in BMJ health & care informatics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Assessing Africa's position in the development of AI-enabled ECG devices.F1000Research · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
Abstract
objectivesAn image-based ECG dataset incorporating visual imperfections common to paper-based ECGs, which are typically scanned or photographed into electronic health records, could facilitate clinically useful artificial intelligence (AI)-ECG algorithm development. This study aimed to create a high-fidelity, synthetic image-based ECG dataset.
methodsECG images were recreated from the PTB-XL database, a signal-based dataset and image manipulation techniques were applied to mimic imperfections associated with ECGs in real-world settings. Clinical Turing tests were conducted to evaluate the fidelity of the synthetic images, and the performance of current AI-ECG algorithms was assessed using synthetic images containing visual imperfections.
resultsGenECG, an image-based dataset containing 21 799 ECGs with visual imperfections encountered in routine clinical care paired with imperfection-free images, was created. Turing tests confirmed the realism of the images: expert observer accuracy of discrimination between real-world and synthetic ECGs fell from 63.9% (95% CI 58.0% to 69.8%) to 53.3% (95% CI 48.6% to 58.1%) over three rounds of testing, indicating that observers could not distinguish between synthetic and real ECGs. The performance of pre-existing algorithms on synthetic (area under the curve (AUC) 0.592, 95% CI 0.421 to 0.763) and real-world (AUC 0.647, 95% CI 0.520 to 0.774) ECG images containing imperfections was limited. Algorithm fine-tuning with GenECG data improved real-world ECG classification accuracy (AUC 0.821, 95% CI 0.730 to 0.913) demonstrating its potential to augment image-based algorithm development. DISCUSSION/
conclusionGenECG is the first synthetic image-based ECG dataset to pass a clinical Turing test. The dataset will enable image-based AI-ECG algorithm development, ensuring utility in low resource areas, prehospital settings and hospital environments where signal data are unavailable.