ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
Ex-vivo validation of nine algorithms for quantifying infarcts with late gadolinium enhancement cardiovascular magnetic resonance.
Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- The severity of post-infarction edema suggests a bimodal pattern, whereas the extent does not.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic ResonanceArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIn cardiovascular magnetic resonance, late gadolinium enhancement (LGE) is the standard method to visualize myocardial infarction (MI). Many algorithms quantifying infarct size in LGE images exist. However, only few algorithms have been validated, i.e., benchmarked against an ex-vivo measurement. Furthermore, the reported algorithm performance varies considerably between studies.
objectivesThe aim of this study was to compare the performance of all infarct measurement algorithms against an ex-vivo measurement and to promote a discourse regarding advantages and disadvantages of individual measurement methods.
methodsMI was induced in 22 pigs. In-vivo LGE imaging was conducted on d0, d3 or d7 post-MI. For ex-vivo validation infarct was measured using high-resolution T1-weighted images. In-vivo infarct size was measured using the full-width at half-maximum (FWHM), n-SD from remote (2,3,5, and 6 SD), feature analysis and combined thresholding (FACT), expectation maximization-weighted A priori information (EWA), Heiberg-08 and Otsu algorithms and manual delineation. No manual adjustments were made to algorithm delineations.
resultsClear differences in variance and bias were observed between algorithm-based methods, and no method performed optimally in this heterogeneous dataset where the best had a bias of -0.48±3.1, -0.3±4.4%, 2.3±4.2% left ventricle for EWA, FWHM, and FACT, respectively. Manual delineation by experienced observers performed well with a bias of 1.9±5.4%.
conclusionEWA, Heiberg-08, FWHM, and FACT all perform on par with manual delineation, however, Heiberg-08, and FWHM are not suitable for phase sensitive inversion recovery images. The technique used to measure infarct size should be disclosed in clinical trials and in original research. Caution should be applied when comparing datasets employing different infarct quantification methods. Manual infarct delineation by experienced readers remains a reliable technique to measure infarct size.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.