ArticleJournal of chromatographic science2025
Extension of an Ultra-High Performance Liquid Chromatography-MS/MS Method for the Determination of C3 Epimers of 25-Hydroxyl Derivatives of Vitamin D in Human Plasma.
Article in Journal of chromatographic science, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Current vitamin D quantification methods do not account for 25-hydroxyl epimers, which can falsely increase concentrations and mask actual deficiencies. Previously, we developed an ultra-high performance liquid chromatography-tandem mass spectrometry method to measure 25(OH)D3, 3-epi-25(OH)D3 and 25(OH)D2; here, we extended this method to include 3-epi-25(OH)D2. Analytes were separated using a Shimadzu UPLC with a Kinetex F5 column (100 × 2.1 mm, 2.6 μm). The mobile phase contained 0.1% formic acid in methanol and water (70:30, v/v). The internal standard, deuterated 25(OH)D3 and analytes were extracted with hexane. Detection was performed by a mass spectrometer equipped with a triple quadrupole after prior electrospray ionization. It demonstrated sufficient precision and spike recovery within and between days, with a coefficient of variation ≤15% and an error of determination ≤18%. The method exhibited linearity in the 2-100-ng/mL concentration range. The limits of quantification and limits of detection were 2 and 1 ng/mL, respectively. Extraction recoveries ranged from 70.05% to 97.13%. The matrix effect, carryover and dilution integrity were evaluated and met the FDA acceptance criteria. The stability of all metabolites in plasma was confirmed after 3 h of storage at room temperature and after three cycles of freezing at -80°C and thawing. Applying the method to clinical samples showed a high 25-hydroxyl epimer derived from vitamin D.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.