Evidence map›Paper›PMID 40443422›Full record

ArticleJournal of oral & maxillofacial research

CBCT Validation Study on Intraclass Correlation for Linear Measurements in Peri-implantitis: an Observational Study.

Amanda Beatriz Rodriguez, Berceste Guler Ayyildiz, Halil Ayyildiz, Aniruddh Narvekar, Mohammed H Elnagar, Michael Schmerman, Grace Viana, Salvador Nares, Tolga Fikret Tözüm

Abstract read
In one paragraph

Article in Journal of oral & maxillofacial research. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Amanda Beatriz RodriguezDepartment of Periodontics, College of Dentistry, University of Illinois Chicago, 60612, ChicagoUSA.
Berceste Guler AyyildizDepartment of Periodontics, College of Dentistry, University of Illinois Chicago, 60612, ChicagoUSA.
Halil AyyildizDepartment of Periodontics, College of Dentistry, University of Illinois Chicago, 60612, ChicagoUSA.
Aniruddh NarvekarDepartment of Periodontics, College of Dentistry, University of Illinois Chicago, 60612, ChicagoUSA.
Mohammed H ElnagarDepartment of Periodontics, College of Dentistry, University of Illinois Chicago, 60612, ChicagoUSA.
Michael SchmermanDepartment of Periodontics, College of Dentistry, University of Illinois Chicago, 60612, ChicagoUSA.
Grace VianaDepartment of Periodontics, College of Dentistry, University of Illinois Chicago, 60612, ChicagoUSA.
Salvador NaresDepartment of Periodontics, College of Dentistry, University of Illinois Chicago, 60612, ChicagoUSA.
Tolga Fikret TözümDepartment of Periodontics, College of Dentistry, University of Illinois Chicago, 60612, ChicagoUSA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: This retrospective observational study aimed to evaluate the reliability and reproducibility of intra-examiner and inter-examiner bone loss measurements in cone-beam computed tomography images over time, on patients with peri-implant defects using two cone-beam computed tomography software programs: 3D Slicer and Dolphin Imaging. Material and Methods: Baseline images were oriented based on implant location and aligned with the palatal or Go-Me plane. Two CBCT volumes were imported and superimposed using landmark-based and surface-based methods, with accuracy assessed through 3D and 2D matching. Measurements of implant diameter, length, and bone thickness at 0, 1, 3, and 5 mm intervals were taken at two-time points by three independent examiners, with reliability assessed using intra-class correlation coefficients. Results: Twenty measurements per 14 cases were evaluated. Each examiner conducted 1,120 measurements with a cumulative total of 3,360 measurements assessed. Significant differences in measurement times were observed, with 3D Slicer requiring more time for superimposition tasks (P < 0.001). Both software programs, however, demonstrated high reliability (intraclass correlation coefficient > 0.80) in inter- and intra-examiner agreement across various bone measurements. Conclusions: Findings emphasize that the high reliability observed with the software and superimposition techniques is directly linked to the calibration and training exercises conducted with the examiners before the study. Dolphin's Imaging automated superimposition was significantly faster than 3D Slicer's manual approach, 3D Slicer offered superior image quality and better differentiation of bone outlines. Both software demonstrated effectiveness in delivering consistent and reproducible measurements, with significant implications for clinical and research applications in implant dentistry.

Indexed as

anatomybonecalibrationperi-implantitistomography

Identifiers

PMID40443422
PMCPMC12118470

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.