Evidence map›Paper›PMID 40440166›Full record

ArticleMicroscopy (Oxford, England)2025

Characterization of the INTPIX4 SOI pixel detector in transmission electron microscopy at 120 and 200 keV.

Yuichi Ishida, Takafumi Ishida, Makoto Kuwahara, Yasuo Arai, Koh Saitoh

Abstract read
In one paragraph

Article in Microscopy (Oxford, England), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yuichi IshidaDepartment of Applied Physics, Graduate School of Engineering, Nagoya University, Furo-Cho, Chikusa, Nagoya 464-8601, Japan.
Takafumi IshidaDepartment of Applied Physics, Graduate School of Engineering, Nagoya University, Furo-Cho, Chikusa, Nagoya 464-8601, Japan.ORCID 0000-0002-0141-3961
Makoto KuwaharaInstitute of Materials and Systems for Sustainability, Nagoya University, Furo-Cho, Chikusa, Nagoya 464-8601, Japan.ORCID 0000-0003-0046-5716
Yasuo AraiAccelerator Laboratory, High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba 305-0801, Japan.
Koh SaitohDepartment of Applied Physics, Graduate School of Engineering, Nagoya University, Furo-Cho, Chikusa, Nagoya 464-8601, Japan.

Funding

Japan Society for the Promotion of ScienceKAKENHI JP21H04637KAKENHI JP22H03868
6 · The paper itself

Abstract

Imaging performance with 120 and 200 keV electrons was evaluated with an integration-type silicon-on-insulator pixel detector called INTPIX4 installed in a conventional transmission electron microscope. We demonstrated that single-electron events can be detected with INTPIX4 quantitatively. The gain and signals of single-electron events were measured. On the basis of the results, the yields of the collected charge for 120 and 200 keV electrons were estimated to be 96±5% and 97±5%, respectively. The modulation transfer function and detective quantum efficiency were also measured. INTPIX4 was clarified to have high detection efficiency and high sensitivity. We also found that it is necessary to use electron beams with energies less than 120 keV for INTPIX4 because multiple scattering of primary electrons at the silicon sensor degrades image resolution. This detector is expected to be applicable to low-dose observations in transmission electron microscopy.

Indexed as

detective quantum efficiencygainmodulation transfer functionsingle-electron eventSOI pixel detectortransmission electron microscopy

Identifiers

PMID40440166
PMCPMC12685149

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.