ArticleJournal of applied clinical medical physics2025

Localization accuracy of 6-second CBCT for lung IGRT with various breathing patterns.

Jihye Koo, Gage Redler, Vladimir Semenenko, Stephen A Rosenberg, Emily Keit, Jacqueline M Andreozzi

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jihye KooDepartment of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, USA.ORCID https://orcid.org/0000-0002-5949-8259
Gage RedlerDepartment of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, USA.ORCID https://orcid.org/0000-0001-8755-9218
Vladimir SemenenkoDepartment of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, USA.
Stephen A RosenbergDepartment of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, USA.
Emily KeitDepartment of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, USA.
Jacqueline M AndreozziDepartment of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe 6-second cone beam computed tomography (CBCT) acquisition of the Ethos HyperSight (Varian Medical Systems, Inc. Palo Alto, CA, USA) on-board imaging system offers benefits, but could be too fast to accurately capture an average target position in a free-breathing lung cancer patient. This study aimed to ascertain whether a 6-second acquisition is appropriate for regularly breathing patients with varying respiration periods. Additionally, breathing patterns that could lead to clinically impactful inaccuracies for image-guided radiation therapy (IGRT) shifts were investigated.

methodsNine regular (sinusoidal) breathing patterns with different respiration rates (8-20 breaths-per-minute) and amplitudes, along with five irregular breathing patterns including a gasp/cough scenario, were tested using a respiratory motion phantom with a 3 cm diameter spherical target. Once the phantom was aligned using the external chassis to remove any default shifts, the 6-second CBCTs with Acuros reconstruction were acquired. Rigid registrations were performed using the 4DCT simulation average/untagged reconstructed image as reference to align to target (simulating clinical lung IGRT setup). Sixty-second CBCTs were also tested to verify the average offsets with conventional practice. The IGRT shifts were compared to 5 mm, a PTV margin typically used for lung tumors.

resultsMinimal (<1.0 mm) shifts were observed for all regular breathing patterns with both 6-second and 60-second CBCT acquisitions. For moderately irregular breathing patterns and the gasp/cough scenario, all shifts were less than 5 mm. Shifts larger than 5 mm were observed in highly irregular breathing patterns, with both 6-second (14%) and 60-second (24%) CBCT acquisitions. Statistical tests showed no significant differences (p > 0.05) between the sizes of shifts made with the two CBCT durations.

conclusionThe 6-second CBCT can effectively and reliably localize a mobile target for regular and moderately-irregular breathers. Cautions should be used for highly irregular breathers, regardless of the duration of CBCT acquisition.

Indexed as

Cone-Beam Computed TomographyImage Processing, Computer-AssistedLung NeoplasmsPhantoms, ImagingRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedRespirationFour-Dimensional Computed TomographyHumansRadiotherapy DosageRadiotherapy, Intensity-Modulated4DCTCBCTIGRTlocalizationrespiratory motion

Identifiers

PMID40439857
PMCPMC12256656

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.