How to handle lipemic CBC samples on Sysmex hematology analyzers?

Vanja Radišić Biljak, Lucija Dolovčak, Iva Bakarić, Ana Nikler, Andrea Saračević, Marija Grdić Rajković

Abstract read
In one paragraph

Article in Advances in laboratory medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Vanja Radišić BiljakDepartment of Medical Laboratory Diagnostics, University Hospital "Sveti Duh", Zagreb, Croatia.ORCID https://orcid.org/0000-0002-3385-0533
Lucija DolovčakDepartment of Medical Biochemistry and Hematology, Faculty of Pharmacy and Biochemistry, University of Zagreb, Zagreb, Croatia.
Iva BakarićDepartment of Medical Biochemistry and Hematology, Faculty of Pharmacy and Biochemistry, University of Zagreb, Zagreb, Croatia.
Ana NiklerDepartment of Medical Laboratory Diagnostics, University Hospital "Sveti Duh", Zagreb, Croatia.ORCID https://orcid.org/0000-0001-6624-863X
Andrea SaračevićDepartment of Medical Laboratory Diagnostics, University Hospital "Sveti Duh", Zagreb, Croatia.ORCID https://orcid.org/0000-0002-1724-148X
Marija Grdić RajkovićDepartment of Medical Biochemistry and Hematology, Faculty of Pharmacy and Biochemistry, University of Zagreb, Zagreb, Croatia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: Lipemia poses a significant preanalytical problem for complete blood count (CBC) measurement due to limited and non-standardized methods for recognition and removal. We aimed to verify the optical hemoglobin (Hb-O) measurements on the Sysmex XN-1000 hematology analyzer (HA) as a possible reliable method for managing lipemic CBC samples. Methods: Ninety CBC samples with varying Hb concentrations were gradually spiked with a lipid emulsion. Measurements were repeated and Hb-O concentrations were recorded. Spiked CBC samples were centrifuged (400 Results: Hb-O showed statistically insignificant and acceptable bias compared to the initial Hb measurement according to the strictest acceptability criteria (-0.4 %, 95 % CI: -1.2-0.3, p=0.2447). The observed bias did not correlate with the degree of lipemia (rho=-0.072, 95 % CI: -0.295 to 0.157, p=0.537). Hemoglobin measured in samples with lipemic plasma replaced by analyzer diluent exhibited minimal, albeit statistically significant, bias (-1.1 %, 95 % CI: -2.0 to (-0.1), p=0.025). The observed bias negatively correlated with the degree of lipemia (rho=-0.369, 95 % CI: -0.550 to (-0.155), p=0.001). The highest unacceptable bias was found in the recalculated hemoglobin values based on the measured plasma hemoglobin (-3.5 %, 95 % CI: -4.1 to (-2.9), p<0.0001). Conclusions: Hb-O measurement is the most reliable measure of lipemia removal in CBC samples on the Sysmex XN-1000 HA.

Indexed as

complete blood count (CBC)hemoglobininterferencelipemia

Identifiers

PMID40438559
PMCPMC12107407

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.