Precision of electromyography according to the calibration approach of neuromuscular monitoring: a randomised prospective agreement study.

Flora T Scheffenbichler, Bernhard Ulm, Laura Borgstedt, Anna Scholze, Nadine Kretsch, Nadine Zia, Viola Friedrich, Magdalena Marb, Stefan J Schaller, Bettina Jungwirth and 1 more

Registry-linked trialAbstract readMulticenter StudyRandomized Controlled Trial
In one paragraph

Trial report in Journal of clinical monitoring and computing, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04911088 (Does Calibration of Electromyography Guided by State Entropy Improve Measurement Precision), which is not on this map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04911088 completednot on this map

Does Calibration of Electromyography Guided by State Entropy Improve Measurement Precision

TypeobservationalSponsorUniversity Hospital UlmRan2022 to 2023Enrolled66ConditionsNeuromuscular Blockade
3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Validity of neuromuscular monitoring: beyond the technology's precision.Journal of clinical monitoring and computing · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Flora T ScheffenbichlerDepartment of Anaesthesiology and Intensive Care Medicine, Faculty of Medicine, University of UIm, Ulm, Germany.ORCID 0000-0003-1128-0565
Bernhard UlmDepartment of Anaesthesiology and Intensive Care Medicine, Faculty of Medicine, University of UIm, Ulm, Germany.ORCID 0000-0002-9396-2510
Laura BorgstedtDepartment of Anaesthesiology and Intensive Care Medicine, TUM School of Medicine and Health, Technical University of Munich, Munich, Germany.ORCID 0009-0008-5646-4118
Anna ScholzeDepartment of Anaesthesiology and Intensive Care Medicine, TUM School of Medicine and Health, Technical University of Munich, Munich, Germany.
Nadine KretschDepartment of Anaesthesiology and Intensive Care Medicine, TUM School of Medicine and Health, Technical University of Munich, Munich, Germany.
Nadine ZiaDepartment of Anaesthesiology and Intensive Care Medicine, Faculty of Medicine, University of UIm, Ulm, Germany.
Viola FriedrichDepartment of Anaesthesiology and Intensive Care Medicine, Faculty of Medicine, University of UIm, Ulm, Germany.
Magdalena MarbDepartment of Anaesthesiology and Intensive Care Medicine, Faculty of Medicine, University of UIm, Ulm, Germany.
Stefan J SchallerDepartment of Anaesthesiology, Intensive Care Medicine and Pain Medicine, Division of General Anaesthesia and Intensive Care Medicine, Medical University of Vienna, Vienna, Austria.ORCID 0000-0002-6683-9584
Bettina JungwirthDepartment of Anaesthesiology and Intensive Care Medicine, Faculty of Medicine, University of UIm, Ulm, Germany.ORCID 0000-0001-9749-7460
Manfred BlobnerDepartment of Anaesthesiology and Intensive Care Medicine, Faculty of Medicine, University of UIm, Ulm, Germany. manfred.blobner@uni-ulm.de.ORCID 0000-0002-0370-5247

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeAnaesthesia providers often complain that quantitative neuromuscular monitoring does not accurately assess neuromuscular function, a problem that can be mitigated by appropriate calibration. However, there are only very limited recommendations for the calibration of quantitative neuromuscular monitoring in clinical routine. Therefore, this multicentre prospective agreement study compared the precision of electromyography using three different calibration approaches.

methodsSixty patients were assigned to one of three investigational calibration approaches: calibration before anaesthesia induction, calibration during anaesthesia induction, i.e., at loss of consciousness and state entropy < 85, or uncalibrated. All patients received electromyography calibration under deep anaesthesia on the second arm (control as recommended for research). The primary endpoint was the repeatability coefficient, which describes the fluctuation of the following train-of-four (TOF) reading. It therefore provides an estimate of the precision of a measurement method. Secondary endpoints included agreement with control calibration and pain at induction.

resultsThe repeatability coefficient at TOF ratios ≥ 0.8 indicated that electromyography monitoring was less precise when TOF readings were uncalibrated (0.124 ± 0.130) or with calibration during induction (0.087 ± 0.104) but was acceptable after calibration before induction (0.075 ± 0.036) compared to those measured after calibration on the contralateral arm (control: 0.072 ± 0.027, 0.061 ± 0.021, and 0.083 ± 0.063, respectively). Recall of pain at anaesthesia induction did not differ between investigational groups.

conclusionThe findings underline the importance of thoroughly performed calibration for precise TOF readings to reliably exclude residual neuromuscular blockade. Electromyography was most precise when calibration was performed under deep anaesthesia (control). If that approach is not possible in the clinical setting, our data suggest that calibration before anaesthesia induction can be considered if previously discussed with the patient. CLINICAL

trial registrationClinical Trials NCT04911088, registered January 6, 2021.

Indexed as

ElectromyographyMonitoring, IntraoperativeNeuromuscular MonitoringAdultAgedAnesthesiaAnesthesia, GeneralCalibrationFemaleHumansMaleMiddle AgedNeuromuscular BlockadeProspective StudiesReproducibility of ResultsCalibrationElectromyographyNeuromuscular blockadeNeuromuscular blocking drugsNeuromuscular monitoring

Identifiers

PMID40437152
PMCPMC12474677

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.