Evidence map›Paper›PMID 40434405›Full record

ArticleMagnetic resonance in medicine2025

SNR-efficient whole-brain pseudo-continuous arterial spin labeling perfusion imaging at 7 T.

Joseph G Woods, Yang Ji, Hongwei Li, Aaron T Hess, Thomas W Okell

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Joseph G WoodsWellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.ORCID https://orcid.org/0000-0002-0329-824X
Yang JiWellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.ORCID https://orcid.org/0000-0003-4134-374X
Hongwei LiWellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.ORCID https://orcid.org/0000-0003-1591-7674
Aaron T HessWellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.ORCID https://orcid.org/0000-0002-9289-5619
Thomas W OkellWellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.ORCID https://orcid.org/0000-0001-8258-0659

Funding

National Natural Science Foundation of China 62401535NIHR Oxford Health Biomedical Research Centre NIHR203316UK BBSRC BB/W019582/1Wellcome TrustWellcome Trust 203139/A/16/ZWellcome Trust 203139/Z/16/ZWellcome Trust and Royal Society 220204/Z/20/Z
6 · The paper itself

Abstract

purposeTo optimize pseudo-continuous arterial spin labeling (PCASL) parameters to maximize SNR efficiency for RF power constrained whole brain perfusion imaging at 7 T.

methodsWe used Bloch simulations of pulsatile laminar flow to optimize the PCASL parameters for maximum SNR efficiency, balancing labeling efficiency and total RF power. The optimization included adjusting the inter-RF pulse spacing (TR

resultsThe optimized PCASL parameters achieved a significant (3.3×) reduction in RF power while maintaining high labeling efficiency. This allowed for longer label durations and minimized deadtime, resulting in a 118% improvement in SNR efficiency in vivo compared to a previously proposed protocol. Additionally, the static tissue response was improved, reducing the required distance between labeling plane and imaging volume.

conclusionThese optimized PCASL parameters provide a robust and efficient approach for whole brain perfusion imaging at 7 T, with significant improvements in SNR efficiency and reduced specific absorption rate burden.

Indexed as

BrainImage Processing, Computer-AssistedMagnetic Resonance AngiographyMagnetic Resonance ImagingPerfusion ImagingAdultAlgorithmsCerebrovascular CirculationComputer SimulationFemaleHealthy VolunteersHumansMaleSignal-To-Noise RatioSpin LabelsSpin Labels7 Teslaperfusionpseudo‐continuous arterial spin labeling (PCASL)SNR efficiencyultra‐high field

Identifiers

PMID40434405
PMCPMC12202723

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.