Evidence map›Paper›PMID 40433802›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2025

In Situ Electrically Resettable Field-Effect Transistor Biosensors for Continuous and Multiplexed Neurotransmitter Detection.

Bo Xiao, Tingxian Li, Xianmao Cao, Yang Zhang, Jianping He, Mengmeng Xiao, Zhiyong Zhang

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Bo XiaoHunan Institute of Advanced Sensing and Information Technology, Xiangtan University, Hunan, 411105, China.
Tingxian LiKey Laboratory for the Physics and Chemistry of Nanodevices and Center for Carbon-based Electronics, Department of Electronics, Peking University, Beijing, 100871, China.
Xianmao CaoSchool of Integrated Circuits, Beijing University of Posts and Telecommunications, Beijing, 100876, China.
Yang ZhangSchool of Integrated Circuits, Beijing University of Posts and Telecommunications, Beijing, 100876, China.
Jianping HeHunan Institute of Advanced Sensing and Information Technology, Xiangtan University, Hunan, 411105, China.
Mengmeng XiaoHunan Institute of Advanced Sensing and Information Technology, Xiangtan University, Hunan, 411105, China.
Zhiyong ZhangHunan Institute of Advanced Sensing and Information Technology, Xiangtan University, Hunan, 411105, China.ORCID https://orcid.org/0000-0003-1622-3447

Funding

National Key Research and Development Program 2022YFB3204402National Key Research and Development Program 2022YFB4401601National Natural Science Foundation of China 62174007National Natural Science Foundation of China 62225101
6 · The paper itself

Abstract

Accurate, real-time detection of neurotransmitters is crucial for elucidating the mechanisms of brain function and tracking the progression of neurological diseases. Biosensors usually face poor reusability induced by difficulties in probe-target separation, hindering their application for continuous monitoring. In this work, a semiconducting carbon nanotube (CNT) film field-effect transistor (FET) biosensor is developed using pH-sensitive aptamers as probes to capture targets. Through tuning the potential of on-chip palladium electrodes, the biosensor facilitates in situ pH modulation and recovery of the sensor interface, which enables an electrically resettable biosensor. The fabricated sensor demonstrates exceptional sensitivity (with femtomolar-level detection limits), high selectivity (specific responses are 20 times stronger than non-specific ones), and excellent reusability (over ten reuse cycles). Furthermore, in vitro detection demonstrates that the biosensor arrays, incorporating regional modifications and pH-sensitive probes, enable the simultaneous detection of several neurotransmitters, including dopamine, serotonin, histamine, and glutamate in complex biological samples. The combination of microfluidic techniques further lowers non-specific adsorption and cross-reactivity, ensuring reliable, repeatable real-time detection. The resettable CNT FET biosensor array holds significant promise for advancing the monitoring of neurotransmitter dynamics, serving as a powerful tool for the early diagnosis and management of neurological disorders.

Indexed as

Biosensing TechniquesNeurotransmitter AgentsTransistors, ElectronicAnimalsHumansHydrogen-Ion ConcentrationNanotubes, CarbonNanotubes, CarbonNeurotransmitter Agentsallosteric DNAfield‐effect transistorneurotransmittersregenerable biosensors

Identifiers

PMID40433802
PMCPMC12376627

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.