ArticleMagnetic resonance in medicine2026
Block-interleaved segmented echo-planar imaging for improved activity detection in submillimeter high-resolution functional MRI at 7 T.
Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Block-interleaved segmented echo-planar imaging for improved activity detection in submillimeter high-resolution functional MRI at 7 T.Magnetic resonance in medicine · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
purposeIsotropic submillimeter high-resolution functional MRI (fMRI) facilitates noninvasive investigation of neuronal activities at the mesoscale level, including cortical columns and laminae. However, the task-evoked functional activity becomes less detectable when using single-shot echo planar imaging (EPI) with parallel imaging techniques such as generalized autocalibrating partially parallel acquisitions (GRAPPA), owing to a reduction in temporal signal-to-noise ratio (tSNR). Although conventional multishot EPI (msEPI) enhances tSNR, it reduces temporal resolution, making it less suitable for fMRI studies involving short-duration stimuli. To overcome this problem, a novel msEPI-based fMRI acquisition and reconstruction method, called block-interleaved segmented EPI (BISEPI), was proposed.
methodsThis technique uses timing information of a block design paradigm during acquisition and reconstruction to preserve both temporal resolution and tSNR. Furthermore, a k-space-based motion correction method is incorporated to mitigate head motion artifacts.
resultsResults from human studies showed that the proposed method reduced g-factor penalties typically observed in GRAPPA-accelerated EPI. It provided high tSNR, improved motion robustness, and enhanced sensitivity to blood oxygen level-dependent signal responses.
conclusionThe proposed method circumvents both conventional msEPI-related and GRAPPA-related problems and enables the detection of blood oxygen level-dependent signal responses at submillimeter spatial resolution. It is effective for paradigms using short-duration, low-power stimuli at 0.7-mm isotropic resolution, and standard-power stimuli at 0.4-mm isotropic resolution.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.