ArticleSensors (Basel, Switzerland)2025
Super-Resolution Image Optimisation Based on Gradient Iterative Fast Diffraction-Free Spot Algorithm.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Diffraction significantly deteriorates the quality of the laser image, causing severe degradation that undermines the theoretical performance parameters of the autofocus system. In this paper, we conduct a comprehensive analysis of the non-uniform features of the images. To enhance the imaging quality of each individual image, we propose a de-diffraction algorithm based on gradient iteration. This algorithm is capable of rapidly removing the interference spots resulting from diffraction and restoring the distorted laser spots. By doing so, it effectively eliminates the inevitable reduction in the autofocus resolution and focusing accuracy caused by diffraction. Furthermore, the proposed calculation model for the intra-localisation interval significantly improves the convergence of the iterative calculation process. Through experiments, it has been verified that, under the same conditions, the interlayer resolution between the reflective surfaces of the samples processed using this algorithm is increased to a quarter of the original value. This remarkable improvement in resolution, which far exceeds the microscope's inherent resolution, demonstrates that the algorithm successfully achieves super-resolution for the microscope.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.