Evidence map›Paper›PMID 40428174›Full record

ArticleBioengineering (Basel, Switzerland)2025

In Vitro and In Silico Analysis of Entrainment Characterization in Injection Jet-Assisted Fontan Circulation.

Arka Das, Ray O Prather, Anthony Damon, Michael Farias, Alain Kassab, Eduardo Divo, William DeCampli

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Arka DasDepartment of Mechanical Engineering, Embry-Riddle Aeronautical University, Daytona Beach, FL 32114, USA.ORCID 0000-0001-7399-3830
Ray O PratherDepartment of Mechanical Engineering, Embry-Riddle Aeronautical University, Daytona Beach, FL 32114, USA.ORCID 0000-0002-5518-4228
Anthony DamonDepartment of Mechanical Engineering, Embry-Riddle Aeronautical University, Daytona Beach, FL 32114, USA.
Michael FariasDepartment of Cardiology, Boston Children's Hospital, Boston, MA 02115, USA.ORCID 0000-0002-4770-8116
Alain KassabDepartment of Mechanical and Aerospace Engineering, University of Central Florida, Orlando, FL 32816, USA.
Eduardo DivoDepartment of Mechanical Engineering, Embry-Riddle Aeronautical University, Daytona Beach, FL 32114, USA.ORCID 0000-0002-6699-4402
William DeCampliThe Heart Institute at Orlando Health Arnold Palmer Hospital for Children, Orlando, FL 32806, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fontan circulation is a fragile system in which imperfections at any of multiple levels may compromise the quality of life, produce secondary pathophysiology, and shorten life span. Increased inferior vena caval pressure itself may play a role in "Fontan failure". This study describes a mock flow loop model (MFL) designed to quantitatively estimate pulmonary flow entrainment induced by continuous and pulsed flow injections. A patient generic 3D-printed phantom model of the total cavopulmonary connection (TCPC) with average dimensions matching those of a 2-4-year-old patient was inserted in an MFL derived from a reduced lumped parameter model (LPM) representing cardiovascular circulation. The LPM comprises four 2-element Windkessel compartments (compliance and resistance), approximating the upper and lower systemic circulations and the right and left pulmonary circulations. The prescribed cardiac output is about 2.3 L/min for a body surface area of 0.675 m2. The injections originate from an external pump through a 7-9 fr catheter, following a strict protocol suggested by the clinical team, featuring a variation in injection rate (flow rate), injection volume, and injection modality (continuous or pulsed). The key measurements in this study are the flow rates sampled at the distal pulmonary arteries, as well as at the upper and lower body boundaries. These measurements were then used to calculate effective entrainment as the difference between the measured and expected flow rates, as well as jet relaxation (rise and fall time of injection). The results show that for continuous or pulsed injections, varying the total volume injected has no significant influence on the entrainment rate across all injection rates. On the other hand, for both injection modalities, increasing the injection rate results in a reduction in entrainment that is consistent across all injected volumes. This study demonstrates the effectiveness of a high-speed injection jet entraining a slow co-flow while determining the potential for fluid buildup, which could ultimately cause an increase in caval pressure. To avoid the increase in caval pressure due to mass accumulation, we added a fenestration to our proposed injection jet shunt-assisted Fontan models. It was found that for a set of well-defined parameters, the jet not only can be beneficial to the local flow, but any adverse effect can be obviated by careful tuning. These results were also cross-validated with similar in silico findings.

Indexed as

congenital heart defectentrainment characteristicsFontan physiologyin silico modelingin vitro modelingsingle ventricle defect

Identifiers

PMID40428174
PMCPMC12109436

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.