Evidence map›Paper›PMID 40428121›Full record

ArticleBioengineering (Basel, Switzerland)2025

An Evaluation of Magnetic Resonance Imaging Dixon Sequence Fat-Water Separation Techniques (T2w Dixon FSTs) to Detect Dorso-Lumbar Structural Lesions in Patients with Axial Spondyloarthritis.

David Fadli, Pierre-Francois Lintingre, Laurence Dallet, Julien Raoult, Julien Gay-Depassier, Nicolas Bouguennec, Lionel Pesquer, Benjamin Dallaudière

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

David FadliCentre D'imagerie Ostéoarticulaire, Clinique du Sport, Bordeaux Mérignac, 2, rue Georges-Négrevergne, 33700 Mérignac, France.
Pierre-Francois LintingreClinique du Sport de Bordeaux-Mérignac, 33700 Mérignac, France.
Laurence DalletCentre de Résonance Magnétique, CNRS/University of Bordeaux, 33000 Bordeaux, France.
Julien RaoultCentre D'imagerie Ostéoarticulaire, Clinique du Sport, Bordeaux Mérignac, 2, rue Georges-Négrevergne, 33700 Mérignac, France.
Julien Gay-DepassierCentre D'imagerie Ostéoarticulaire, Clinique du Sport, Bordeaux Mérignac, 2, rue Georges-Négrevergne, 33700 Mérignac, France.ORCID 0009-0007-5553-4578
Nicolas BouguennecClinique du Sport de Bordeaux-Mérignac, 33700 Mérignac, France.ORCID 0000-0002-8300-5653
Lionel PesquerClinique du Sport de Bordeaux-Mérignac, 33700 Mérignac, France.
Benjamin DallaudièreCentre D'imagerie Ostéoarticulaire, Clinique du Sport, Bordeaux Mérignac, 2, rue Georges-Négrevergne, 33700 Mérignac, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe aim of this study was to assess and compare the diagnostic accuracy of two MRI techniques for identifying structural bone lesions (fatty lesions [BMFs], subchondral erosions [BMEs], sclerosis [BMS], and ankylosis [A]) in the dorso-lumbar joints. This assessment specifically focused on the application of MRI Dixon sequence fat-water separation techniques (T2w Dixon FSTs) when acquiring T1-weighted (T1w) images as the reference standard, among patients diagnosed with axial spondyloarthritis (SpA).

methodsConducted at a single center, this study involved the recruitment of patients who underwent both spinal and sacroiliac (SI) joint MRI between 2019 and 2022, with follow-up continuing until 2023. In 2023, three independent readers reassessed the initial MRI datasets to evaluate specific radiological features of SpA. They recorded confidence estimates regarding the use of T2w Dixon FSTs when acquiring T1w images. The centralized MRI interpretations were then compared to established rheumatologic diagnoses.

resultsA total of 73 patients (42 men and 31 women) were included in the study. The mean sensitivity, specificity, and accuracy of T2w Dixon FSTs (fat-only images) were at least 75%, 100%, and 96%, respectively, based on the 2023 assessment for all considered items. The diagnostic performance of T2w Dixon FSTs was comparable to that of T1w images.

conclusionsThe diagnostic performance of T2w Dixon FSTs (fat-only images) matched that of T1w images not only in assessing structural and fatty lesions, but also in the evaluation of subchondral erosions, sclerosis, and ankylosis in the dorso-lumbar joints of patients with a rheumatologic diagnosis of SpA. These findings suggest the potential avoidance of T1-weighted images when employing multi-parameter, multi-sequence imaging, such as the Dixon sequence.

Indexed as

DIXONfatmagnetic resonance imaging (MRI)spondyloarthritis

Identifiers

PMID40428121
PMCPMC12109157

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked