Evidence map›Paper›PMID 40428075›Full record

ArticleBioengineering (Basel, Switzerland)2025

Effects of a Wearable Assistive Device on Postural Control and Stability During Symmetric and Asymmetric Intermittent Trunk Flexion Tasks.

Pranav Madhav Kuber, Ehsan Rashedi

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Pranav Madhav KuberDepartment of Industrial and Systems Engineering, Rochester Institute of Technology, 1 Lomb Memorial Dr, Rochester, NY 14623, USA.ORCID 0000-0001-6572-0912
Ehsan RashediDepartment of Industrial and Systems Engineering, Rochester Institute of Technology, 1 Lomb Memorial Dr, Rochester, NY 14623, USA.ORCID 0000-0002-2998-4993

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Assistive devices, such as Exoskeletons (EXOs) can enhance endurance, but could inadvertently alter body mechanics, compromise balance, and elevate fall risk, particularly under fatigue. We evaluated effects of an EXO on postural stability during standing still and sustained trunk flexion tasks as users become fatigued during intermittently performed tasks. As trunk bending is common across many occupational/routine tasks, a repetitive 45° trunk flexion task was selected. In this controlled laboratory study, symmetric and asymmetric trunk flexion tasks were performed by twelve participants with a Back-support EXO until medium-high fatigue level (7/10 on Borg CR10 scale). Outcomes showed that the device increased trunk flexion durations (~16~25%), and upper-body movement beyond intended position. EXO-use improved stability by reducing maximum deviation (~22%) and mean velocity (~57%) of Center of Pressure (COP) co-ordinates. Asymmetric trunk flexion without assistance led to highest mean velocity of COP during fatigued state, but the same remained lower (~67%) with EXO-use, even with fatigue. The device decreased variance of COP during in medial/lateral direction (~44%), but increased the same in anterior/posterior direction by the same amount. Efforts in this study contribute towards understanding implications of using assistive devices for improving human performance across diverse applications.

Indexed as

awkward posturebalancebiomechanicsexoskeletonmotion analysistrunk bending

Identifiers

PMID40428075
PMCPMC12109500

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked