Clinical Bedside Benchmarking Test for Measuring the Total Hemoglobin Concentration.

Elena Stawschenko, Stefan S Niemuth, Benjamin Kern, Berit Bode, Frank Dörries, Christoph Marquetand, Kristina Kusche-Vihrog, Hartmut Gehring, Philipp Wegerich

Abstract read
In one paragraph

Article in Healthcare (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Elena StawschenkoDepartment of Anaesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Luebeck, 23538 Luebeck, Germany.
Stefan S NiemuthDepartment of Anaesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Luebeck, 23538 Luebeck, Germany.
Benjamin KernMedical Sensors and Devices Laboratory, Luebeck University of Applied Sciences, 23562 Luebeck, Germany.ORCID 0000-0003-1930-3100
Berit BodeDepartment of Anaesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Luebeck, 23538 Luebeck, Germany.
Frank DörriesNorthern Scientific Tec & Integration GmbH, Kollaustr. 11-13, 22525 Hamburg, Germany.
Christoph MarquetandDepartment of Cardiology, Angiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Luebeck, 23538 Luebeck, Germany.ORCID 0000-0002-6279-9239
Kristina Kusche-VihrogInstitute of Physiology, University of Luebeck, 23562 Luebeck, Germany.
Hartmut GehringDepartment of Anaesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Luebeck, 23538 Luebeck, Germany.
Philipp WegerichInstitute of Biomedical Engineering, University of Luebeck, 23562 Luebeck, Germany.

Funding

European Union - Regional Development Fund (ERDF) and the Federal State Government of Land Schleswig-Holstein for the project "Cross- Innovation-Center- TANDEM Phase III (TANDEM III - CIC)" 124 20 003
6 · The paper itself

Abstract

objectiveAccurate total hemoglobin concentration (ctHb) measurement is critical for clinical decision-making, particularly in acute care, where immediate therapeutic decisions are required. This study evaluated previously established laboratory-based accuracy criteria for ctHb measurements in routine clinical practice at an interdisciplinary operative intensive care unit (IO-ICU), and with particular attention to significantly reduced hemoglobin concentrations.

methodRemaining blood from blood gas analysis (BGA) cuvettes was collected directly at the ICU bedside. From these initial samples, three clinically relevant measurement scenarios were established: direct bedside measurement (Group 01), elevated ctHb levels (Group 02), and lowered ctHb concentrations below 9 g/dl (Group 03). The samples were analyzed using the GEM 4000, GEM 5000 (Werfen GmbH, Muenchen, Germany), ABL90 Flex plus (Radiometer GmbH, Krefeld, Germany), HemoCue Hb 201+, and XN 9000/9100 (Sysmex Deutschland GmbH, Norderstedt, Germany) automatic hematology analyzers. Since each measurement device inherently possesses systematic deviations, no single analyzer was defined as an absolute reference. Instead, the mean value across all tested measurement systems was utilized as a best-fit reference (REF) value.

resultsA total of 120 data pairs from 40 ICU patients were analyzed using regression analyses, Bland and Altman (B&A) methods, and tolerance level analysis (TLA). The results demonstrated strong concordance among the evaluated measurement devices across the examined ctHb spectrum (~1-18 g/dL). Moderate systematic deviations identified by B&A analysis were most pronounced at critically low ctHb levels (<6 g/dL). A key outcome was the determination of 95% prediction intervals (PIs), representing a quantifiable range of uncertainties for future bedside measurements. The PIs for Group 03 "low" were in the range of ±7% (relative difference) or ±0.38 g/dL (absolute difference).

conclusionThis study effectively translates previous laboratory findings into clinical practice, highlighting the practical utility of PIs to guide the accurate interpretation of bedside ctHb measurements under acute care conditions.

Indexed as

accuracyconcentrationhemoglobinintensive care unitmachine learningprediction interval