Evidence map›Paper›PMID 40426132›Full record

ArticleBiomedical engineering online2025

Investigation of bending angle algorithm and path planning for puncture needles in transjugular intrahepatic portosystemic shunt.

Qinmei Liao, Bing Li, Xihao Hu, Xiaoyun Huang, Jiacheng Guo, Yuanzhong Zhu, Wenjing He

Abstract read
In one paragraph

Article in Biomedical engineering online, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Qinmei Liao *School of Medical Imaging, North Sichuan Medical College, Nanchong, 637000, China.
Bing Li *Department of Interventional Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, 637002, China.
Xihao HuSchool of Medical Imaging, North Sichuan Medical College, Nanchong, 637000, China.
Xiaoyun HuangSchool of Medical Imaging, North Sichuan Medical College, Nanchong, 637000, China.
Jiacheng GuoSchool of Medical Imaging, North Sichuan Medical College, Nanchong, 637000, China.
Yuanzhong ZhuSchool of Medical Imaging, North Sichuan Medical College, Nanchong, 637000, China.
Wenjing HeSchool of Medical Imaging, North Sichuan Medical College, Nanchong, 637000, China. hwj@nsmc.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeDesign an algorithm to calculate the bending angle of the puncture needle for transjugular intrahepatic portosystemic shunt (TIPS) procedures and achieve three-dimensional visualized path planning. MATERIALS AND

methodsBased on enhanced CT images, a thresholding segmentation method was used to perform three-dimensional reconstruction of the hepatic vasculature, with the target puncture point selected by the interventional physician. The puncture needle was modeled using second-order Bézier curves and arcs. Subsequently, the bending points were selected, and the optimal bending angles were calculated based on the target puncture point. The puncture pathway was then verified and visualized in three dimensions using Mimics software. Data from 32 patients who successfully underwent TIPS procedures were retrospectively collected for clinical validation and statistical analysis.

resultsThe error between the tip position of the puncture needle catheter modeled with Bézier curves and the actual puncture needle was 0.15 cm, while the error for the arc modeling was 0.19 cm. The optimal bending angle of the puncture needle calculated by this algorithm was validated in Mimics software, successfully achieving path planning. Among the 32 patients, the difference between the actual bending angle of the puncture needle and the calculated bending angle was 1.06° ± 1.82° (95% CI 0.41-1.72°). The equivalence test results indicated that there was a significant equivalence between the measured angle and the angle calculated by the algorithm (p < 0.001).

conclusionThis study successfully designed an algorithm for calculating the bending angle of the puncture needle in TIPS procedures, which demonstrated equivalence with the clinically observed bending angles.

Indexed as

AlgorithmsMechanical PhenomenaNeedlesPortasystemic Shunt, Transjugular IntrahepaticPuncturesAdultAgedFemaleHumansImaging, Three-DimensionalMaleMiddle AgedRetrospective StudiesTomography, X-Ray ComputedBending angleBézier curvePath planningPuncture needleTIPS

Identifiers

PMID40426132
PMCPMC12117853

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.