Evidence map›Paper›PMID 40425980›Full record

ArticleEJNMMI physics2025

Dual-ended readout TOF-DOI PET detectors based on 3.2 mm and 1.6 mm pitch LYSO arrays.

Haibo Wang, Jiahao Xie, Jinyi Qi, Simon R Cherry, Junwei Du

Abstract read
In one paragraph

Article in EJNMMI physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Haibo WangDepartment of Biomedical Engineering, University of California at Davis, Davis, CA, 95616, USA. habwang@ucdavis.edu.ORCID http://orcid.org/0009-0006-9182-9237
Jiahao XieDepartment of Biomedical Engineering, University of California at Davis, Davis, CA, 95616, USA.ORCID http://orcid.org/0009-0005-2575-2027
Jinyi QiDepartment of Biomedical Engineering, University of California at Davis, Davis, CA, 95616, USA.ORCID http://orcid.org/0000-0002-5428-0322
Simon R CherryDepartment of Biomedical Engineering, University of California at Davis, Davis, CA, 95616, USA.ORCID http://orcid.org/0000-0002-0155-5644
Junwei DuDepartment of Biomedical Engineering, University of California at Davis, Davis, CA, 95616, USA.ORCID http://orcid.org/0000-0002-1719-8266

Funding

Staff InvestigatorsP30CA093373 · NCI · UNIVERSITY OF CALIFORNIA DAVIS · PI Gina M Dayton · 2002 to 2026
$84.9M
A 0.5 mm resolution total-body small-animal PETR01EB031961 · NIBIB · UNIVERSITY OF CALIFORNIA AT DAVIS · PI DU, JUNWEI · 2022 to 2025
$2.6M
Maximizing sensitivity for ultra-low dose PET imagingR01EB028806 · NIBIB · UNIVERSITY OF CALIFORNIA AT DAVIS · PI DU, JUNWEI · 2020 to 2024
$2.3M
NCI NIH HHS P30 CA093373NIBIB NIH HHS R01 EB028806NIBIB NIH HHS R01 EB031961
6 · The paper itself

Abstract

backgroundThe image quality of positron emission tomography (PET) can be significantly enhanced by using time-of-flight (TOF) and depth-of-interaction (DOI) information. PET detectors are pivotal in determining the TOF and DOI capabilities of PET scanners.

methodsThis study developed and evaluated TOF-DOI PET detectors based on the dual-ended readout method and lutetium-yttrium oxyorthosilicate (LYSO) arrays with two different pitches and reflector configurations. Specifically, the performance of detectors based on three types of LYSO arrays with 20 mm thickness, 8 × 8 arrays with a 3.2 mm pitch, 16 × 16 arrays with a 1.6 mm pitch and normal reflectors, and 16 × 16 arrays with a 1.6 mm pitch and partial short reflectors, were assessed. Hamamatsu S14161-3050-08 silicon photomultiplier arrays were used as the photodetectors, and PETsys TOFPET2 was used as the readout electronics.

resultsThe flood histograms showed that all crystals in the three types of LYSO arrays were clearly resolved. The detectors based on the 8 × 8 LYSO arrays provided a coincidence timing resolution (CTR) of 207 ± 5 ps and a DOI resolution of 3.9 ± 0.6 mm. The detectors based on the 16 × 16 LYSO arrays with normal reflectors provided a CTR of 218 ± 7 ps and a DOI resolution of 2.6 ± 0.2 mm. In comparison, the detector based on the 16 × 16 LYSO arrays with partial short reflectors provided a CTR of 228 ± 11 ps and a DOI resolution of 2.9 ± 0.3 mm, and superior crystal resolvability compared to the detectors based on the 16 × 16 LYSO arrays with normal reflectors.

conclusionThese detectors are promising candidates for developing whole-body and brain PET scanners, offering effective sensitivity and uniform spatial resolution improvements across the field-of-view.

Indexed as

Coincidence timing resolution (CTR)Depth-of-interaction (DOI)Dual-ended readoutPositron emission tomography (PET)Time-of-flight (TOF)

Identifiers

PMID40425980
PMCPMC12116964

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.