Evidence map›Paper›PMID 40423623›Full record

ArticleInvestigative ophthalmology & visual science2025

Iris Crypts Could Reduce the Chance of Angle Closure: A Computational Biomechanics Study Derived From Clinical and Human Iris Data.

Royston K Y Tan, Tin A Tun, Fabian A Braeu, Shamira A Perera, Michaël J A Girard

Abstract read
In one paragraph

Article in Investigative ophthalmology & visual science, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Royston K Y TanSingapore Eye Research Institute, Singapore National Eye Centre, Singapore.
Tin A TunSingapore Eye Research Institute, Singapore National Eye Centre, Singapore.
Fabian A BraeuSingapore Eye Research Institute, Singapore National Eye Centre, Singapore.
Shamira A PereraDuke-NUS Medical School, Singapore.
Michaël J A GirardSingapore Eye Research Institute, Singapore National Eye Centre, Singapore.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To investigate the effect of crypts during pupil constriction and dilation on the potential for angle closure by performing finite element analysis using clinical and experimental data on human tissues. Methods: A computational model was developed to determine the influence of small crypts (surface area of ∼0.015 mm2) and large crypts (surface area of 0.300 mm2) on the anterior chamber angles during pupil dilation. The model needed permeability data from human subjects; hence, 21 enucleated human eyes (72 hours postmortem) were procured and subjected to a flow setup previously reported. Finally, 66 subjects were recruited to measure pupil constriction and dilation levels from optical coherence tomography (OCT) videos. Results: The hydraulic permeability of the human iris stroma was determined to be 2.55 ± 1.93 × 10-5 mm2/Pa · s. The average iris constriction and dilation durations were 0.710 ± 0.213 seconds and 1.24 ± 0.401 seconds, respectively, with pupil diameter changes of 1.16 ± 0.39 mm and 0.75 ± 0.27 mm, respectively. The computational models had starting anterior chamber angles of 51.30° and final anterior chamber angles of 26.81° once steady state had been reached. In an extreme case with decreased anterior border layer (ABL) permeability, the anterior chamber angle narrowed to 12.37°, but the presence of crypts kept the angle above 20.36°, highlighting the potential of crypts in preventing angle closure. Conclusions: Our findings on the biomechanics of crypts in the iris may drive the development of novel treatments by altering ABL morphology, providing an alternative bypass for angle closure prevention in high-risk patients.

Indexed as

Glaucoma, Angle-ClosureIrisPupilAdultAgedAnterior ChamberBiomechanical PhenomenaComputer SimulationFemaleFinite Element AnalysisHumansIntraocular PressureMaleMiddle AgedTomography, Optical Coherence

Identifiers

PMID40423623
PMCPMC12124145

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.