Evidence map›Paper›PMID 40422486›Full record

ArticleEntropy (Basel, Switzerland)2025

Exergetic Analysis and Design of a Mechanical Compression Stage-Application for a Cryogenic Air Separation Plant.

Adalia Andreea Percembli Chelmuș, Arthur Dupuy, Lavinia Grosu, Daniel Dima, Alexandru Dobrovicescu

Abstract read
In one paragraph

Article in Entropy (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Adalia Andreea Percembli ChelmușDepartment of Engineering Thermodynamics, National University of Science and Technology Politehnica București, 060042 Bucharest, Romania.ORCID 0009-0002-5317-5659
Arthur DupuyLaboratoire Energétique Mécanique Electromagnétisme (LEME), IUT de Ville d'Avray, 50 rue de Sèvres, 92410 Ville d'Avray, France.ORCID 0009-0000-2110-0092
Lavinia GrosuLaboratoire Energétique Mécanique Electromagnétisme (LEME), IUT de Ville d'Avray, 50 rue de Sèvres, 92410 Ville d'Avray, France.ORCID 0000-0002-0861-3413
Daniel DimaDepartment of Engineering Thermodynamics, National University of Science and Technology Politehnica București, 060042 Bucharest, Romania.
Alexandru DobrovicescuDepartment of Engineering Thermodynamics, National University of Science and Technology Politehnica București, 060042 Bucharest, Romania.

Funding

National University of Science and Technology POLITEHNICA Bucharest PubArt Program
6 · The paper itself

Abstract

This study focuses on the compression area of a cryogenic air separation unit (ASU). The mechanism of exergy consumption in the compressor was revealed. The influence of the compression ratio and of the isentropic efficiency per stage give arguments for proper choice of these decisional parameters. For the purchase cost of the compressor, an exergoeconomic correlation based on the exergetic product represented by the compression ratio and the isentropic efficiency as the Second Law coefficient of performance was used instead of the common thermo-economic one based only on the cost of materials. The impact of the suction temperature on the compressor operating performance is shown, making the gap between the compression stage and the associated intercooler. After optimization of the global system, a specific exergy destruction is assigned to each inter-stage compression cooler. To fit this optimum exergy consumption, a design procedure for the inter-stages and final coolers based on the number of heat transfer units (NTU-ε) method and the number of exergy units destroyed (NEUD) is shown. Graphs are provided that make the application of the method straightforward and much easier to use compared to the usual logarithmic mean temperature difference. A 25% increase in the compression ratio per stage leads to a decrease in the exergy efficiency of 3%, while the purchase cost of the compressor rises by 80%. An increase in the isentropic efficiency of the compressor from 0.7 to 0.85 leads to an increase in the exergetic performance coefficient of 21%, while the compressor purchase cost triples.

Indexed as

compressorcryogenicsexergoeconomicsexergy analysisheat exchanger efficiency

Identifiers

PMID40422486
PMCPMC12111542

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.