Evidence map›Paper›PMID 40422060›Full record

ArticleBiosensors2025

A Highly Sensitive Electrochemical Immunosensor for Cortisol Detection.

Pritu Parna Sarkar, Ali Ashraf, Ahmed Hasnain Jalal, Fahmida Alam, Nazmul Islam

Abstract read
In one paragraph

Article in Biosensors, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Pritu Parna SarkarDepartment of Mechanical Engineering, The University of Texas Rio Grande Valley, Edinburg, TX 78539, USA.ORCID 0009-0004-4680-9929
Ali AshrafDepartment of Mechanical Engineering, The University of South Florida, Tampa, FL 33620, USA.
Ahmed Hasnain JalalDepartment of Electrical & Computer Engineering, The University of Texas Rio Grande Valley, Edinburg, TX 78539, USA.ORCID 0000-0003-1857-1621
Fahmida AlamDepartment of Electrical & Computer Engineering, The University of Texas Rio Grande Valley, Edinburg, TX 78539, USA.
Nazmul IslamDepartment of Electrical & Computer Engineering, The University of Texas Rio Grande Valley, Edinburg, TX 78539, USA.ORCID 0000-0001-9237-1949

Funding

National Science Foundation (NSF) . UTRGV Biomedical Engineering Start-up grant, and Bentsen Endowment ERI 2138574
6 · The paper itself

Abstract

In this research, an interdigitated gear-shaped working electrode is presented for cortisol sensing. Overall, the sensor was designed in a three-electrode system and was fabricated using direct laser scribing. A synthesized conductive ink based on graphene and polyaniline was further employed to enhance the electrochemical performance of the sensor. Scanning electron microscopy (SEM) and Fourier transform infrared (FTIR) spectroscopy were employed for physicochemical characterization of the laser-induced graphene (LIG) sensor. Cortisol, a biomarker essential in detecting stress, was detected both in phosphate-buffered saline (PBS, pH = 7.4) and human serum within a linear range of 100 ng/mL to 100 µg/mL. Ferri/ferrocyanide was employed as the redox probe to detect cortisol in PBS. The electrochemical performance of the developed sensor was assessed via differential pulse voltammetry (DPV), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and chronoamperometry. The electrochemical performance demonstrates high sensitivity and selectivity alongside strong repeatability (relative standard deviation (RSD) = 3.8%, n = 4) and reproducibility (RSD = 5.85%, n = 5). Overall, these results highlight the sensor's reliability, high sensitivity, and repeatability and reproducibility in the detection of cortisol. The sensor successfully detected cortisol in the complex medium of human serum and effectively distinguished it in a ternary mixture containing cortisol and dopamine. Also, the use of direct laser writing on Kapton film makes the approach cost-effective and thus disposable, making it suitable for chronic stress diagnostics and neurological research applications.

Indexed as

Biosensing TechniquesElectrochemical TechniquesHydrocortisoneAniline CompoundsElectrodesGraphiteHumansAniline CompoundsGraphiteHydrocortisonepolyanilineantibody-based immunosensorcortisolflexible sensor applicationsprintable sensor designsensor coatings

Identifiers

PMID40422060
PMCPMC12110703

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.