Evidence map›Paper›PMID 40416315›Full record

ArticleFrontiers in bioengineering and biotechnology2025

Research on target localization and adaptive scrubbing of intelligent bathing assistance system.

Ping Li, Shikai Feng, Hongliu Yu

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Ping LiDepartment of Biomedical Engineering, Changzhi Medical College, Changzhi, China.
Shikai FengInstitute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, China.
Hongliu YuInstitute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Bathing is a primary daily activity. Existing bathing systems are limited by their lack of intelligence and adaptability, reliance on caregivers, and the complexity of their control algorithms. Although visual sensors are widely used in intelligent systems, current intelligent bathing systems do not effectively process depth information from these sensors. Methods: The scrubbing task of the intelligent bath assist system can be divided into a pre-contact localization phase and a post-contact adaptive scrubbing phase. YOLOv5s, known for its ease of deployment and high accuracy, is utilized for multi-region skin detection to identify different body parts. The depth correction algorithm is designed to improve the depth accuracy of RGB-D vision sensors. The 3D position and pose of the target point in the RGB camera coordinate system are modeled and then transformed to the robot base coordinate system by hand-eye calibration. The system localization accuracy is measured when the collaborative robot runs into contact with the target. The self-rotating end scrubber head has flexible bristles with an adjustable length of 10 mm. After the end is in contact with the target, the point cloud scrubbing trajectory is optimized using cubic B-spline interpolation. Normal vectors are estimated based on approximate triangular dissected dyadic relations. Segmented interpolation is proposed to achieve real-time planning and to address the potential effects of possible unexpected movements of the target. The position and pose updating strategy of the end scrubber head is established. Results: YOLOv5s enables real-time detection, tolerating variations in skin color, water vapor, occlusion, light, and scene. The localization error is relatively small, with a maximum value of 2.421 mm, a minimum value of 2.081 mm, and an average of 2.186 mm. Sampling the scrubbing curve every 2 mm along the x-axis and comparing actual to desired trajectories, the y-axis shows a maximum deviation of 2.23 mm, which still allows the scrubbing head to conform to the human skin surface. Discussion: The study does not focus on developing complex control algorithms but instead emphasizes improving the accuracy of depth data to enhance localization precision.

Indexed as

B-spline curvedeep learningdepth correctionhand-eye calibrationintelligent bathing assistancemulti-region skin detection

Identifiers

PMID40416315
PMCPMC12098527

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.