Evidence map›Paper›PMID 40408298›Full record

ArticleThe Journal of the Acoustical Society of America2025

Bioinspired flow-sensing capacitive microphone.

Johar Pourghader, Weili Cui, Mahdi Farahikia, Junpeng Lai, Morteza Karimi, Changhong Ke, Ronald Miles

Abstract read
In one paragraph

Article in The Journal of the Acoustical Society of America, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Johar PourghaderDepartment of Mechanical Engineering, Binghamton University, Binghamton, New York 13902, USA.ORCID 0000-0002-3486-8153
Weili CuiDepartment of Mechanical and Facility Engineering, State University of New York, Maritime College, Bronx, New York 10465, USA.
Mahdi FarahikiaDivision of Engineering Programs, State University of New York at New Paltz, New Paltz, New York 12561, USA.ORCID 0000-0002-0867-868X
Junpeng LaiDepartment of Mechanical Engineering, Binghamton University, Binghamton, New York 13902, USA.ORCID 0000-0003-1130-3042
Morteza KarimiDepartment of Mechanical Engineering, Binghamton University, Binghamton, New York 13902, USA.ORCID 0000-0002-8745-0818
Changhong KeDepartment of Mechanical Engineering, Binghamton University, Binghamton, New York 13902, USA.ORCID 0000-0002-5170-9859
Ronald MilesDepartment of Mechanical Engineering, Binghamton University, Binghamton, New York 13902, USA.ORCID 0000-0001-7245-9345

Funding

Capacitive Pressure/Velocity Probe for Acoustic Measurements in the Human Ear CanalR01DC017720 · NIDCD · STATE UNIVERSITY OF NY,BINGHAMTON · PI MILES, RONALD N, SHERA, CHRISTOPHER A · 2019 to 2023
$1.5M
NIDCD NIH HHS R01 DC017720
6 · The paper itself

Abstract

Inspired by the auditory systems of small animals, such as spiders, the tachinid fly, Ormia ochracea, and mosquitoes, a novel low-noise, flow-sensing capacitive MEMS microphone capable of sensing acoustic particle velocity is introduced. Unlike conventional microphones that have a diaphragm for sensing sound pressure, this design consists of a thin, porous, movable structure that is intended to be driven by viscous forces as a result of the sound-induced flow. This viscous force then rotates the movable structure around a middle central hinge and creates a change in capacitance caused by a relative motion between neighboring beams. The whole structure is made of one layer of silicon using a silicon-on-insulator (SOI) wafer using photolithography technology with a device layer thickness of 5 μm. The movable part has dimensions of 0.7 mm × 1.2 mm and is placed above a cavity inside the bulk silicon that facilitates the flow of sound particles. This microphone responds to flow (a vector) rather than pressure (a scalar). Ultimately, experimental results demonstrate a sensitivity of approximately 5 mV/Pa, a noise floor between 10-4 and 10-5 Pa/Hz, and directivity ratios reaching up to 77 at 2000 Hz, underscoring its potential for high-performance acoustic applications.