Controlling sharpness, SNR, and specific absorption rate for 3D fast-spin echo at 7T by end-to-end learning.

Peter Dawood, Martin Blaimer, Jürgen Herrler, Patrick Liebig, Simon Weinmüller, Shaihan Malik, Peter M Jakob, Moritz Zaiss

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Peter DawoodInstitute of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.ORCID https://orcid.org/0000-0001-7127-607X
Martin BlaimerMagnetic Resonance and X-ray Imaging Department, Fraunhofer Institute for Integrated Circuits IIS, Division Development Center X-Ray Technology, Würzburg, Germany.ORCID https://orcid.org/0000-0002-6360-9871
Jürgen HerrlerSiemens Healthineers, Erlangen, Germany.ORCID https://orcid.org/0000-0002-4620-8216
Patrick LiebigSiemens Healthineers, Erlangen, Germany.ORCID https://orcid.org/0000-0001-7342-3715
Simon WeinmüllerInstitute of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.ORCID https://orcid.org/0009-0002-1163-0772
Shaihan MalikDepartment of Biomedical Engineering, King's College, London, UK.ORCID https://orcid.org/0000-0001-8925-9032
Peter M JakobExperimental Physics 5, University of Würzburg, Würzburg, Germany.ORCID https://orcid.org/0000-0002-3481-5545
Moritz ZaissInstitute of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.ORCID https://orcid.org/0000-0001-9780-3616

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo non-heuristically identify dedicated variable flip angle (VFA) schemes optimized for the point-spread function (PSF) and SNR of multiple tissues in 3D FSE sequences with very long echo trains at 7T.

methodsThe proposed optimization considers predefined specific absorption rate (SAR) constraints and target contrast using an end-to-end learning framework. The cost function integrates components for contrast fidelity (SNR) and a penalty term to minimize image blurring (PSF) for multiple tissues. By adjusting the weights of PSF/SNR cost-function components, PSF- and SNR-optimized VFAs were derived and tested in vivo using both the open-source Pulseq standard on two volunteers as well as vendor protocols on a 7T MRI system with parallel transmit extension on three volunteers.

resultsPSF-optimized VFAs resulted in significantly reduced image blurring compared to standard VFAs for T2-weighted while maintaining contrast fidelity. Small white and gray matter structures, as well as blood vessels, were more visible with PSF-optimized VFAs. Quantitative analysis shows that the optimized VFA yields 50% less deviation from a reference PSF (sinc) than the standard VFA. The SNR-optimized VFAs yielded images with significantly improved SNR in a white and gray matter region relative to standard (77.1 vs. 40.7, respectively) as trade-off for elevated image blurring.

conclusionThis study demonstrates the potential of end-to-end learning frameworks to optimize VFA schemes in very long echo trains for 3D FSE acquisition at 7T in terms of PSF and SNR. It paves the way for fast and flexible adjustment of the trade-off between PSF and SNR for 3D FSE.

Indexed as

BrainImage Processing, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance ImagingAdultAlgorithmsHealthy VolunteersHumansMaleSignal-To-Noise Ratiofast spin echooptimal controlsequence optimizationultra high fieldvariable flip angles

Identifiers

PMID40408006
PMCPMC12202734

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.