Evidence map›Paper›PMID 40402206›Full record

ArticlePediatric cardiology2026

Agreement Between 2D and 3D Echocardiography in Measuring Dimensions of the Patent Ductus Arteriosus in Infants.

Stephan Juergensen, Christine Springston, Michael J Bunker, Phillip Moore, Shafkat Anwar

Abstract readComparative Study
In one paragraph

Article in Pediatric cardiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Stephan JuergensenDivision of Cardiology, Department of Pediatrics, Columbia University Vagelos College of Physicians and Surgeons and New York Presbyterian-Morgan Stanley Children's Hospital, New York, NY, USA. Smj2186@cumc.columbia.edu.ORCID http://orcid.org/0000-0002-0121-5850
Christine SpringstonDivision of Cardiology, Department of Pediatrics, University of California San Francisco, San Francisco, CA, USA.
Michael J BunkerCenter for Advanced 3D+ Technologies, University of California San Francisco, San Francisco, CA, USA.
Phillip MooreDivision of Cardiology, Department of Pediatrics, University of California San Francisco, San Francisco, CA, USA.
Shafkat AnwarDivision of Cardiology, Department of Pediatrics, University of California San Francisco, San Francisco, CA, USA. shafkat.anwar@ucsf.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The patent ductus arteriosus (PDA) is a common cardiac lesion in neonates, which may require intervention for patency, or closure in the neonatal period. Two-dimensional echocardiography (2DE) is standard for PDA imaging. Three-dimensional echocardiography (3DE) is increasingly used for assessing complex anatomy and pre-procedural planning; however, there are limited data on the value and accuracy of 3DE of the PDA in infants. We aimed to determine the degree of agreement between 2 and 3DE in measuring common dimensions of the PDA in infants. Infants < 1-year-old, > 32 weeks corrected gestational age (CGA), and > 1 kg with a known PDA were enrolled prospectively for imaging by 2DE and 3DE. Images were collected at the parasternal short axis (PSAX) and suprasternal notch (SSN). Dimensions were measured at the pulmonic (PA) and aortic (Ao) end. Interclass correlation (ICC), Bland-Altman (BA), and coefficient of variability (COV) assessed interobserver variability. 2DE to 3DE association was assessed by BA. Twenty-nine subjects were enrolled and had complete data sets, median CGA 39.4 weeks (IQR 38.3-41.7), median weight 3.250 kg (IQR 2.870-4.295). ICC for all 2D and 3D images in PSAX and SSN views was strong with narrow limits of agreement (LOA). BA showed low bias and generally narrow LOA. Each observer's 2DE- 3DE comparison yielded low bias and narrow LOA. There was generally no statistically significant difference in PDA size when 2D and 3D images were compared for each observer. Our data suggest 2DE and 3DE have strong agreement and paired 2DE- 3DE images show low bias and limited variability for common PDA measures. Previous work in this area has focused on larger patients, and this data begins to build a foundation for use of 3DE for anatomic assessment and possible interventional planning in smaller patients with PDAs. Further study should aim to compare 3DE agreement with CT or angiography, and at variable subject size, ductal size, and ductal type.

Indexed as

Ductus Arteriosus, PatentEchocardiographyEchocardiography, Three-DimensionalFemaleGestational AgeHumansInfantInfant, NewbornMaleObserver VariationProspective StudiesReproducibility of Results3D echocardiographyCongenital heart diseasePatent ductus arteriosusPediatric echocardiographyProcedural planning

Identifiers

PMID40402206
PMCPMC12855442

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.