Evidence map›Paper›PMID 40401205›Full record

ArticleARYA atherosclerosis2025

Evaluation of novel ultrathin, biodegradable polymer tetriflex (sirolimus-eluting stent) optimization using intravascular ultrasound (IVUS) in short coronary lesion (≤ 20mm) vs. long coronary lesion (≥ 20mm): Tetriflex IVUS study.

Najeeb Ullah Sofi, Mohit Sachan, Santosh Kumar Sinha, Mukesh J Jha, Umeshwar Pandey, Mahmodullah Razi, Awadesh K Sharma, Puneet Aggarwal, Praveen Shukla, Rakesh Varma

Abstract read
In one paragraph

Article in ARYA atherosclerosis, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Najeeb Ullah SofiDepartment of Cardiology, LPS Institute of Cardiology, G.S.V.M. Medical College, Kanpur, Uttar Pradesh, India.
Mohit SachanDepartment of Cardiology, LPS Institute of Cardiology, G.S.V.M. Medical College, Kanpur, Uttar Pradesh, India.
Santosh Kumar SinhaDepartment of Cardiology, LPS Institute of Cardiology, G.S.V.M. Medical College, Kanpur, Uttar Pradesh, India.
Mukesh J JhaDepartment of Cardiology, LPS Institute of Cardiology, G.S.V.M. Medical College, Kanpur, Uttar Pradesh, India.
Umeshwar PandeyDepartment of Cardiology, LPS Institute of Cardiology, G.S.V.M. Medical College, Kanpur, Uttar Pradesh, India.
Mahmodullah RaziDepartment of Cardiology, LPS Institute of Cardiology, G.S.V.M. Medical College, Kanpur, Uttar Pradesh, India.
Awadesh K SharmaDepartment of Cardiology, LPS Institute of Cardiology, G.S.V.M. Medical College, Kanpur, Uttar Pradesh, India.
Puneet AggarwalDepartment of Cardiology, RML Institute of Medical Science, New Delhi, India.
Praveen ShuklaDepartment of Cardiology, LPS Institute of Cardiology, G.S.V.M. Medical College, Kanpur, Uttar Pradesh, India.
Rakesh VarmaDepartment of Cardiology, LPS Institute of Cardiology, G.S.V.M. Medical College, Kanpur, Uttar Pradesh, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIntravascular ultrasound (IVUS)-guided percutaneous coronary intervention (PCI) is useful for stent optimization. Outcomes of the ultrathin Supralimus Tetriflex stent (Sahajanand Medical Technologies Pvt. Ltd., India) using IVUS were evaluated among patients with short (≤ 20 mm) versus long lesions (≥ 20 mm).

methodsA total of 207 patients underwent PCI, and IVUS was performed post-deployment. The primary outcome was optimal stent deployment, defined as (a) mean surface area (MSA) >5.0 mm²; (b) plaque burden <50%; (c) complete apposition; and (d) no edge dissection. Secondary outcomes were target lesion failure (TLF)-a composite of cardiac death, target vessel myocardial infarction (TVMI), and target lesion revascularization (TLR)-stent thrombosis, and major adverse cardiovascular events (MACE; a composite of death, MI, stent thrombosis, and repeat revascularization).

resultsSuboptimal deployment was significantly more frequent among patients with longer lesions (30.1% vs. 23.3%; p=0.03) due to higher rates of malapposition (17.3% vs. 10.6%) and MSA <5 mm² (9.6% vs. 7.7%). Following post-dilatation, suboptimal deployment was observed in 7.6% and 5.8% of patients, respectively. Residual plaque burden was 4.5% and 5.7%, respectively. The MSA in both groups was 6.3 mm² and 6.5 mm². Minimum and mean stent expansions were 82.1% versus 81.7% and 106.3% versus 109.8%, respectively, with no significant differences. TLF and stent thrombosis were observed in 0.9% versus 0.9% and 2.9% versus 3.8% of patients, respectively, with no significant differences. However, MACE was significantly higher (10.5% vs. 8.7%; p=0.05) among patients with longer lesions.

conclusionSupralimus Tetriflex stent has very good optimal deployment based on angiogram and becomes better with IVUS imaging, making it safe among long lesions (≥ 20mm).

Indexed as

Intravascular ultrasoundMajor adverse cardiovascular eventsStent optimizationStent thrombosisTarget lesion failureTarget lesion revascularization

Identifiers

PMID40401205
PMCPMC12091251

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.