Evidence map›Paper›PMID 40400985›Full record

ArticleJournal of thoracic disease2025

Efficacy of Amplatzer device for endobronchial treatment of hemoptysis: case series.

Lev Freidkin, Ramzi Zamaereh, Shimon Izhakian, Dror Rosengarten, Barak Pertzov, Shai M Amor, Alex Krolik, Moshe Heching, Mordechai R Kramer

Abstract read
In one paragraph

Article in Journal of thoracic disease, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Lev FreidkinPulmonary Division, Rabin Medical Center, Petah Tikva, Israel.ORCID https://orcid.org/0000-0002-7402-3876
Ramzi ZamaerehPulmonary Division, Rabin Medical Center, Petah Tikva, Israel.
Shimon IzhakianPulmonary Division, Rabin Medical Center, Petah Tikva, Israel.ORCID https://orcid.org/0000-0003-1150-1057
Dror RosengartenPulmonary Division, Rabin Medical Center, Petah Tikva, Israel.
Barak PertzovPulmonary Division, Rabin Medical Center, Petah Tikva, Israel.ORCID https://orcid.org/0000-0002-3077-3616
Shai M AmorPulmonary Division, Rabin Medical Center, Petah Tikva, Israel.
Alex KrolikPulmonary Division, Rabin Medical Center, Petah Tikva, Israel.
Moshe Heching *Pulmonary Division, Rabin Medical Center, Petah Tikva, Israel.ORCID https://orcid.org/0000-0001-8073-3973
Mordechai R Kramer *Pulmonary Division, Rabin Medical Center, Petah Tikva, Israel.ORCID https://orcid.org/0000-0003-2376-2393

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Hemoptysis is a potentially life-threatening condition attributable to various pulmonary diseases. Bronchoscopy plays an important role in hemoptysis management to localize and treat the source of bleeding. While deployment of endobronchial blockers to achieve hemostasis has been widely described, the repurpose of the Amplatzer Methods: We conducted a retrospective analysis of patients admitted to our tertiary medical center with massive or sub-massive hemoptysis where an AVPD was deployed during bronchoscopy to achieve hemostasis. We collected demographic data, medical history, hemoptysis etiology, bronchoscopy procedures, hemostasis outcomes and follow-up. Results: Fifteen patients with a median age of 60 years (range, 24-86 years) with massive or sub-massive hemoptysis were treated with endobronchial deployment of an AVPD. Eleven patients (73%) suffered from massive hemoptysis. AVPD deployment successfully achieved concurrent hemostasis in 14 (93%) cases, with four patients requiring subsequent surgical or endovascular treatments to achieve definitive hemostasis. In 5 (33%) cases, the AVPD was subsequently removed after a median period of 23 days, with no recurrent hemoptysis. Three patients (20%) expired within a week of the bronchoscopy for causes unrelated to the AVPD deployment or hemoptysis. Conclusions: Endobronchial deployment of AVPD is an effective management tool for hemoptysis either as a definitive treatment or as a bridge to surgical or endovascular treatment. To our knowledge, this is the first case series of AVPD use for hemoptysis management. Further research encompassing a larger patient population including comparison of results with standard of care treatment is required to further substantiate our results.

Indexed as

Amplatzerbronchoscopycase seriesHemoptysis

Identifiers

PMID40400985
PMCPMC12090146

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.