Evidence map›Paper›PMID 40395421›Full record

ArticleEuropean heart journal. Digital health2025

Artificial intelligence-enhanced six-lead portable electrocardiogram device for detecting left ventricular systolic dysfunction: a prospective single-centre cohort study.

Jaehyun Lim, Hak Seung Lee, Ga In Han, Sora Kang, Jong-Hwan Jang, Yong-Yeon Jo, Jeong Min Son, Min Sung Lee, Joon-Myoung Kwon, Seung-Pyo Lee

Abstract read
In one paragraph

Article in European heart journal. Digital health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jaehyun LimDivision of Cardiology and Cardiovascular Centre, Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0002-9450-5653
Hak Seung LeeArtificial Intelligence and Big Data Research Centre, Sejong Medical Research Institute, Bucheon, Republic of Korea.ORCID https://orcid.org/0000-0002-2200-6601
Ga In HanArtificial Intelligence and Big Data Research Centre, Sejong Medical Research Institute, Bucheon, Republic of Korea.
Sora KangArtificial Intelligence and Big Data Research Centre, Sejong Medical Research Institute, Bucheon, Republic of Korea.
Jong-Hwan JangArtificial Intelligence and Big Data Research Centre, Sejong Medical Research Institute, Bucheon, Republic of Korea.
Yong-Yeon JoArtificial Intelligence and Big Data Research Centre, Sejong Medical Research Institute, Bucheon, Republic of Korea.
Jeong Min SonArtificial Intelligence and Big Data Research Centre, Sejong Medical Research Institute, Bucheon, Republic of Korea.
Min Sung LeeArtificial Intelligence and Big Data Research Centre, Sejong Medical Research Institute, Bucheon, Republic of Korea.
Joon-Myoung KwonArtificial Intelligence and Big Data Research Centre, Sejong Medical Research Institute, Bucheon, Republic of Korea.
Seung-Pyo LeeDivision of Cardiology and Cardiovascular Centre, Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0002-5502-3977

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aims: The real-world effectiveness of the artificial intelligence model based on electrocardiogram (AI-ECG) signals from portable devices for detection of left ventricular systolic dysfunction (LVSD) requires further exploration. Methods and results: In this prospective, single-centre study, we assessed the diagnostic performance of AI-ECG for detecting LVSD using a six-lead hand-held portable device (AliveCor KardiaMobile 6L). We retrained the AI-ECG model, previously validated with 12-lead ECG, to interpret the 6-lead ECG inputs. Patients aged 19 years or older underwent six-lead ECG recording during transthoracic echocardiography. The primary outcome was the area under the receiver operating characteristic curve (AUROC) for detecting LVSD, defined as an ejection fraction below 40%. Of the 1716 patients recruited prospectively, 1635 were included for the final analysis (mean age 60.6 years, 50% male), among whom 163 had LVSD on echocardiography. The AI-ECG model based on the six-lead portable device demonstrated an AUROC of 0.924 [95% confidence interval (CI) 0.903-0.944], with 83.4% sensitivity (95% CI 77.8-89.0%) and 88.7% specificity (95% CI 87.1-90.4%). Of the 1079 patients evaluated using the AI-ECG model based on the conventional 12-lead ECG, the AUROC was 0.962 (95% CI 0.947-0.977), with 90.1% sensitivity (95% CI 85.0-95.2%) and 91.1% specificity (95% CI 89.3-92.9%). Conclusion: The AI-ECG model constructed with the six-lead hand-held portable ECG device effectively identifies LVSD, demonstrating comparable accuracy to that of the conventional 12-lead ECG. This highlights the potential of hand-held portable ECG devices leveraged with AI as efficient tools for early LVSD screening.

Indexed as

Artificial intelligenceEchocardiographyElectrocardiographyHeart failure

Identifiers

PMID40395421
PMCPMC12088721

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.