ArticleCureus2025
Use of Motion Management to Model Unmanaged Motion: Dosimetric Consequences of Unmanaged Prostate Motion Assessed Using Real-Time Radiotherapy Adaptation Data.
Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This case report presents a novel application of intrafraction prostate motion data from the Radixact Synchrony real-time radiotherapy treatment adaptation system (Accuray Inc., Sunnyvale, USA) to evaluate the dosimetric consequences if a specific patient treatment had been delivered without the use of real-time adaptation, i.e., if the prostate motion had been unmanaged. The patient included in this study was selected from a dataset of 50 completed prostate Radixact Synchrony treatments for which intrafraction motion had been collected. This patient was identified as having the highest proportion of fractions where the target motion exhibited continuous drift, a form of motion that is particularly likely to degrade treatment accuracy, especially when combined with the continuous superior motion of the Radixact treatment couch. Target trajectory data from the Synchrony real-time adaptation system were collected for this patient using the Delivery Analysis software (Accuray Inc.) and used, via a novel application of a deformation vector field that took couch motion interplay into account, to perform several voxel-wise deformations of the patient's planned treatment dose distribution to cover various intrafraction motion scenarios for two treatment regimens. For the standard hypofractionated prostate radiotherapy treatment regimen used in this patient's clinical treatment, 60 Gy in 20 fractions, this study showed that target coverage would have been compromised for this patient had the Synchrony system not been used to adapt the radiation beam to account for the observed prostate motions. Evidently, this patient benefited from the use of real-time target tracking even though an ultra-hypofractionated stereotactic body radiotherapy (SBRT) regimen was not used in this case. By rescaling the patient's hypofractionated dose distribution to model an ultra-hypofractionated SBRT treatment regimen, this study also suggests that a substantial and clinically unacceptable target underdosage might have occurred if this patient had been treated with SBRT and 3 mm margins without the use of the Synchrony system. This result points to an even greater benefit from Synchrony real-time adaptation for SBRT prostate treatments.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.