Evidence map›Paper›PMID 40394372›Full record

SynthesisNeurosurgical review2025

Potential interference of spinal cord and sacral stimulators with cardiac implantable electronic devices: a systematic review.

Negin Eissazade, Mohammad Rohani, Seyed-Mohammad Fereshtehnejad, Mohammad Javad Sinaeefar, Seyedehnarges Tabatabaee

Abstract readSystematic Review
PubMed Publisher
In one paragraph

Synthesis in Neurosurgical review, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Negin EissazadeCellular and Molecular Research Center, Iran University of Medical Sciences, Tehran, Iran.
Mohammad RohaniSkull Base Research Center, Five Senses Health Institute, Iran University of Medical Sciences, Tehran, Iran.
Seyed-Mohammad FereshtehnejadDivision of Clinical Geriatrics, Department of Neurobiology, Care Sciences and Society (NVS), Karolinska Institutet, Stockholm, Sweden.
Mohammad Javad SinaeefarDepartment of Neurology, School of Medicine, Iran University of Medical Sciences, Tehran, Iran.
Seyedehnarges TabatabaeeDepartment of Neurology, School of Medicine, Iran University of Medical Sciences, Tehran, Iran. Nrgstaba@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Spinal cord stimulation (SCS) and sacral nerve stimulation (SNS) are neuromodulation therapies increasingly used for treatment-resistant chronic pain and urinary or fecal incontinence. Despite their benefits, concerns remain regarding their potential interference with cardiac implantable electronic devices (CIEDs), including permanent pacemakers (PPMs) and implantable cardioverter defibrillators (ICDs), potentially leading to inappropriate pacing or shocks. This systematic review aimed to assess documented interactions between these devices to guide clinical decision-making and enhance patient safety. A comprehensive search of PubMed, Embase, Scopus, Cochrane Library, and Web of Science was conducted for studies published up to November 2024. Eligible studies included adult patients with both SCS or SNS and CIEDs. Due to methodological heterogeneity, findings were summarized descriptively, and meta-analysis was not performed. The quality of the included studies was evaluated using Joanna Briggs Institute (JBI) critical appraisal tools. A total of 30 studies involving 119 participants were included. Among 107 patients with SCS, two instances of interference (1.86%) were reported: one with unipolar and one with bipolar configurations. In both cases, the interference was successfully managed through adjustments of stimulation parameters. No interference or adverse cardiac events were reported in 12 patients with concurrent SNS and CIEDs. The risk of interactions between SCS/SNS and ICDs/PPMs appears to be low and manageable with appropriate device programming and monitoring. Nevertheless, the absence of standardized monitoring protocols and methodological heterogeneity limits the generalizability of findings. Future research should focus on developing standardized protocols for assessing device compatibility to ensure safe integration of neuromodulation and cardiac therapies. Clinical trial number Not applicable.

Indexed as

Defibrillators, ImplantableElectric Stimulation TherapyPacemaker, ArtificialSpinal Cord StimulationHumansCardiac implantable electronic devicesDefibrillatorNeuromodulationPacemakerSacral nerve stimulationSpinal cord stimulation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.