ArticleClinical orthopaedics and related research2025
Do Cumulative Revision Rate and First-time Re-revision Rate Vary Between Short and Standard Femoral Stem Lengths? A Multinational Registry Study.
Article in Clinical orthopaedics and related research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Bone-Sparing Hip Arthroplasty in Young and Active Patients: A Narrative Review.Journal of clinical medicine · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAdvocates of short-stem THA suggest that these devices preserve proximal femoral bone for future revisions. This contention is as yet unsupported by robust evidence, and ultimately, it will be irrelevant if short-stem THA increases the overall risk of premature revision. To our knowledge, large, registry-based efforts have yet to explore the types of stems used in first-time stem revision as well as the survivorship of short versus standard-length femoral stems in THA. QUESTIONS/PURPOSES: (1) Which stems are used in the first stem revision of primary short-stem and standard-stem THAs? (2) What is the overall cumulative revision rate (CRR) of primary short-stem THAs compared with primary standard-stem THAs? (3) What is the overall cumulative re-revision rate of primary short-stem THAs compared with primary standard-stem THAs?
methodsPatients with short-stem THAs, defined as a short stem with mainly metaphyseal fixation, registered in the Australian Orthopaedic Association National Joint Replacement Register (AOANJRR), the Dutch Arthroplasty Register (Landelijke Registratie Orthopedische Interventies [LROI]), or the Swedish Arthroplasty Register (SAR) between January 2007 and December 2022 were included (n = 15,771), as well as a propensity score-matched cohort (1:2) with standard-stem THAs, defined as a stem with a standard length (n = 31,542). Groups were matched on sex, age, year of procedure, diagnosis, bearing material, and surgical approach. After matching, the groups did not differ in terms of age (mean ± SD 63 ± 11 versus 64 ± 11 years), sex (48% [7546 of 15,771] male versus 48% [15,093 of 31,542] male), and diagnosis (93% [14,655 of 15,771] osteoarthritis [OA] versus 94% [29,585 of 31,542] OA). We used those three registries because all are high-quality national arthroplasty registries with high levels of completeness. Also, the AOANJRR is the only registry globally that reports on short-stem THA as its own entity. The type of stem used in revision surgery was classified as standard stem (< 160 mm) or long stem (≥ 160 mm). Overall CRR of primary THAs at 12 years of follow-up and overall CRR of all first-time revisions at 5 years were calculated using Kaplan-Meier survival analyses. Any type of revision was used as endpoint.
resultsIn first-time stem revisions of the short-stem THAs, a standard stem was used more often (58% [116 of 201]) than in the revision of standard-stem THAs (46% [149 of 322]; p = 0.01). The 12-year overall CRRs between primary short-stem and standard-stem THAs did not differ (4.7% [95% confidence interval (CI) 4.0% to 5.5%] versus 5.1% [95% CI 4.5% to 5.7%], respectively; p = 0.20). The overall CRR for a second revision at 5 years also did not differ when primary short-stem THAs were compared with standard-stem THAs (20.9% [95% CI 16.8% to 25.8%]) versus 20.4% [95% CI 17.3% to 23.9%]; p = 0.80).
conclusionIn light of these findings, there may be a perceived benefit of using short stems in primary THA if a revision is later required, as the short stems included in this study were to a higher degree revised using a standard (more bone-sparing) stem. Further, the first and second overall CRR of the studied short-stem THAs did not differ from that of standard-stem THAs, also supporting use of short-stem THA. Further research, preferably multinational registry-based studies, should be performed to confirm our findings. LEVEL OF EVIDENCE: Level III, therapeutic study.