Measurement of bilirubin in cerebrospinal fluid using the oxidase method on automated chemistry system advia XPT.
Article in Practical laboratory medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background and aim: Evaluate the diagnostic performance of automated, quantitative bilirubin measurement, modified to extend its lower measurement ranges, in cerebrospinal fluid (CSF) using the Siemens analyzer Advia XPT. Results were compared with the gold standard spectrophotometry for diagnosis of subarachnoid haemorrhage (SAH). Method: Eighty clinical samples were analyzed on an Advia XPT, and results were compared to spectrophotometric results using the Agilent Cary 100 bio system. Method performance at low concentrations were evaluated using diluted control material and patient plasma and CSF samples. ROC curve analysis determined a suitable cutoff. Result: Evaluation of low-concentration performance, below 2 μmol/L on Advia XPT, showed a measurement bias of -1.0 %, and a linear regression equation of y = 0.843x + 0.0351 (R Conclusion: Quantitative measurement of bilirubin in CSF using the bilirubin oxidase method on the automated Advia XPT platform perform well, with the analysis of low concentrations of bilirubin displaying a high precision and a high concordance with the results of spectrophotometry. These preliminary findings are indicative of the merits of quantitative measurement, that warrants further study of its diagnostic potential as an alternative to the more cumbersome spectrophotometry for diagnosing SAH.