Evidence map›Paper›PMID 40384662›Full record

ArticleQuantitative imaging in medicine and surgery2025

Performance of S-MAR in metal artifact reduction for intracranial aneurysm patients after endovascular embolization: a cross-sectional spectral computed tomography study.

Hanpei Zheng, Xinli Zhang, Shen Gui, Ming Yang, Jing Wang

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hanpei Zheng *Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Xinli Zhang *Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Shen GuiClinical and Technical Support, Philips Healthcare, Wuhan, China.
Ming Yang *Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Jing Wang *Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Metal artifacts caused by endovascular coils in intracranial aneurysms pose challenges in the accurate assessment of adjacent vessels. This study evaluated the performance of S-MAR, a novel post-processing technology that combines the advantages of three traditional techniques; that is, virtual monochromatic imaging (VMI) of spectral computed tomography (CT), metal artifact reduction (MAR), and subtraction algorithm. This study aimed to investigate its performance under different conditions and validate its accuracy. Methods: In total, 94 patients who had undergone cerebral computed tomography angiography (CTA) with dual-layer detector spectral CT were enrolled in this retrospective study. A total of 106 coils were found, and 67 patients had accompanying stents. Fifty patients underwent both digital subtraction angiography (DSA) and CTA within 6 months. Conventional CTA images, VMI [range, 40-110 kilo electron volt (keV)], and virtual non-enhanced images were generated and then post-processed to S-MAR, using the MAR technique and a subtraction algorithm. The contrast-to-noise ratio (CNR) and background noise were calculated. The maximum diameter, minimum diameter, and mean diameter of the adjacent vessels were measured. The coil artifact (CA) score was qualitatively assessed by two radiologists independently. Results: Compared to conventional images, S-MAR (40-70 keV) had significantly reduced metal artifacts, improved CNR, and lower CA scores (P<0.001). In S-MAR, a range of 60-70 keV is more suitable than 40-50 keV for coils with a diameter >8 mm. S-MAR also provides more accurate luminal quantitative measurements (maximum, minimum and mean diameter) and shows good consistency with DSA [intraclass correlation coefficients: 0.845 (0.783, 0.884), 0.947(0.876, 0.954), and 0.956 (0.875, 0.962)]. Conclusions: S-MAR enhances vessel visualization and measurement accuracy. Our findings support its use in clinical practice for evaluating intracranial aneurysms post-embolization.

Indexed as

cerebral aneurysmdigital subtraction angiography (DSA)Metal artifact reduction (MAR)metal coilsubtraction

Identifiers

PMID40384662
PMCPMC12084747

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.