Evidence map›Paper›PMID 40384598›Full record

Trial reportNeurourology and urodynamics2025

Portable Ultrasound Bladder Volume Measurement Over Entire Volume Range Using a Deep Learning Artificial Intelligence Model in a Selected Cohort: A Proof of Principle Study.

Hyun Ju Jeong, Aeran Seol, Seungjun Lee, Hyunji Lim, Maria Lee, Seung-June Oh

Abstract readClinical Trial
In one paragraph

Trial report in Neurourology and urodynamics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hyun Ju JeongDepartment of Medical Device Development, Seoul National University College of Medicine, Seoul, Republic of Korea.ORCID http://orcid.org/0009-0008-3818-9626
Aeran SeolDepartment of Obstetrics and Gynecology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Seungjun LeeDepartment of Obstetrics and Gynecology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Hyunji LimDepartment of Obstetrics and Gynecology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Maria LeeDepartment of Obstetrics and Gynecology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
Seung-June OhDepartment of Medical Device Development, Seoul National University College of Medicine, Seoul, Republic of Korea.

Funding

This study is supported by the Korea Medical Device Development Fund (Project Number: 1711135009).
6 · The paper itself

Abstract

objectiveWe aimed to prospectively investigate whether bladder volume measured using deep learning artificial intelligence (AI) algorithms (AI-BV) is more accurate than that measured using conventional methods (C-BV) if using a portable ultrasound bladder scanner (PUBS). PATIENTS AND

methodsPatients who underwent filling cystometry because of lower urinary tract symptoms between January 2021 and July 2022 were enrolled. Every time the bladder was filled serially with normal saline from 0 mL to maximum cystometric capacity in 50 mL increments, C-BV was measured using PUBS. Ultrasound images obtained during this process were manually annotated to define the bladder contour, which was used to build a deep learning AI model. The true bladder volume (T-BV) for each bladder volume range was compared with C-BV and AI-BV for analysis.

resultsWe enrolled 250 patients (213 men and 37 women), and a deep learning AI model was established using 1912 bladder images. There was a significant difference between C-BV (205.5 ± 170.8 mL) and T-BV (190.5 ± 165.7 mL) (p = 0.001), but no significant difference between AI-BV (197.0 ± 161.1 mL) and T-BV (190.5 ± 165.7 mL) (p = 0.081). In bladder volume ranges of 101-150, 151-200, and 201-300 mL, there were significant differences in the percentage of volume differences between [C-BV and T-BV] and [AI-BV and T-BV] (p < 0.05), but no significant difference if converted to absolute values (p > 0.05). C-BV (R

conclusionFollowing image pre-processing, deep learning AI-BV more accurately estimated true BV than conventional methods in this selected cohort on internal validation. Determination of the clinical relevance of these findings and performance in external cohorts requires further study.

trial registrationThe clinical trial was conducted using an approved product for its approved indication, so approval from the Ministry of Food and Drug Safety (MFDS) was not required. Therefore, there is no clinical trial registration number.

Indexed as

Deep LearningLower Urinary Tract SymptomsUrinary BladderAdultAgedAlgorithmsFemaleHumansMaleMiddle AgedOrgan SizeProof of Concept StudyProspective StudiesUltrasonographyartificial intelligencedeep learningultrasonographyurinary bladder

Identifiers

PMID40384598
PMCPMC12264466

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked