Evidence map›Paper›PMID 40384286›Full record

ArticleAdvanced healthcare materials2025

Resorbable 3D-Printed Osteosynthetic Plates for Rib Fracture Repair.

Emily K Augustine, Adrian Camarena, Taylor R Klein, Lillian Kang, Georgia Wimmer, Natasha C Stinson, Joseph S Fernandez-Moure, Matthew L Becker

Abstract read
In one paragraph

Article in Advanced healthcare materials, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Emily K AugustineThomas Lord Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC, 27708, USA.
Adrian CamarenaDepartment of Surgery, Duke University School of Medicine, Durham, NC, 27708, USA.
Taylor R KleinThomas Lord Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC, 27708, USA.
Lillian KangDepartment of Surgery, Duke University School of Medicine, Durham, NC, 27708, USA.
Georgia WimmerDepartment of Chemistry, Duke University, Durham, NC, 27708, USA.
Natasha C StinsonDepartment of Chemistry, Duke University, Durham, NC, 27708, USA.
Joseph S Fernandez-MoureDepartment of Surgery, Duke University School of Medicine, Durham, NC, 27708, USA.
Matthew L BeckerThomas Lord Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC, 27708, USA.ORCID 0000-0003-4089-6916

Funding

Resorbable, Phsophorylated Poly(ester urea) Surgical Adhesive to Enhance Fracture HealingK08AR079609 · NIAMS · DUKE UNIVERSITY · PI FERNANDEZ-MOURE, JOSEPH S. · 2021 to 2025
$835k
NIAMS NIH HHS K08 AR079609NIAMS NIH HHS L30 AR083193NIH HHS 1K08AR079609-01
6 · The paper itself

Abstract

Rib fractures are common among blunt chest trauma patients and are a hallmark of severe thoracic injury with high morbidity and mortality rates. The standard treatment of most rib fracture cases is limited to pain control and respiratory support, with the surgical stabilization of rib fractures (SSRF) using titanium plates reserved for severely injured patients. Although SSRF has been shown to improve long-term patient outcomes, its expanded use has been limited by the invasiveness of the procedure and a lack of safe and effective resorbable fixation materials. While resorbable metal and polymeric plates have each been used in the clinic, many failures have been reported and challenges remain to control the mechanical properties of the plate during the degradation process. The 3D printing of resorbable, fumarate-based copolyester-hydroxyapatite (HAp) composite osteosynthetic plates for use in SSRF is presented, and assess their efficacy in vivo in a rabbit rib fracture model. Compared to rigid titanium fixation plates, ribs fixed with 3D printed composite plates elicit fracture calluses with decreased inflammatory response, enhanced osseointegration, and bone morphometry at 2- and 4-weeks post-fracture comparable to clinically used titanium plates.

Indexed as

Absorbable ImplantsBone PlatesFracture Fixation, InternalPrinting, Three-DimensionalRib FracturesAnimalsDurapatiteRabbitsTitaniumDurapatiteTitaniumadditive manufacturingfumarate‐based copolyesterrib fracturesurgical stabilization of rib fractures

Identifiers

PMID40384286
PMCPMC12208221

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.