Evidence map›Paper›PMID 40383528›Full record

ArticleBone & joint research2025

Stem introducer designs and surgical technique play a significant role in achieving the optimal implant-cement interface.

Bernard H van Duren, Kevin Ilo, Sophie Walker, Mark Higgins, Benjamin V Bloch, Andrew R Manktelow, Hemant G Pandit

Abstract read
In one paragraph

Article in Bone & joint research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Bernard H van DurenNottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK.
Kevin IloNottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK.
Sophie WalkerNottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK.
Mark HigginsNottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK.
Benjamin V BlochNottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK.
Andrew R ManktelowNottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK.
Hemant G PanditLeeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aims: Periprosthetic fracture is a major contributor to reoperation with polished taper slip (PTS) cemented stems, which is the most used fixation technique in many countries. A clear cause for this has yet to be established. A significant variation exists between PTS stem designs, associated fractured rates among them, and the design of introducers used. Achieving a conforming implant-cement interface (ICI) is crucial to ensure optimal function of PTS implants. Movement of the stem within the setting cement during surgery should be uniplanar, and should not be associated with any unplanned deviations. This is in part controlled by the stem introducer design, which potentially contributes to excess movement and ICI compromise. The aim of this study was to assess movement when using different introducer designs. Methods: We compared four stem introducer designs used with two commonly used PTS stems. The stems were mounted using a silicone rubber compound to simulate setting cement at different timepoints (early = soft, late = hard). The stem tips were left clear, and an inertial measurement unit attached to measure acceleration, angular velocity, and rotation. Participating surgeons (n = 16) were asked to maintain stem position for ten seconds before releasing the introducer. Results: Simulation of soft cement conditions showed a mean root mean square (RMS) value ranging from 0.10 g to 0.30 g for acceleration, 12.75°/s to 67.94°/s for angular velocity, and 2.02° to 6.03° for rotation with significant differences noted between different stem introducers. Simulation of later insertion during the curing process (hard) showed a similar pattern, with a lower overall range of motion. Conclusion: Our results showed that introducer design had a significant impact on stem movement within the setting cement. Furthermore, its removal earlier in the setting reaction resulted in increased movement. These findings highlight the importance of instrument design and correct technique in achieving the optimal ICI.

Identifiers

PMID40383528
PMCPMC12086010

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.