ArticleVirology journal2025
Comparison of dried blood spot (DBS) and plasma HIV-1 viral load measurements using Roche COBAS AmpliPrep/COBAS TaqMan assay, Northwest Ethiopia.
Article in Virology journal, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionQuantitative determination of HIV-1 viral load measurements using plasma samples has been widely applicable for prompt monitoring at baseline and following initiation of highly active antiretroviral therapy (HAART). However, improper mixing of whole blood with anticoagulants during plasma sample processing, as well as limited access to specialized health facilities might hinder HIV diagnosis services. Considering its higher stability and increased accessibility in areas with poor laboratory settings, the dried blood spot (DBS) sample might be a suitable alternative approach for periodic monitoring of HIV-1 viral load measurements. Thus, in this study, we aimed to compare the quantitative determination of HIV-1 RNA levels using plasma and DBS samples among people living with HIV in Northwest Ethiopia.
methodsAn institutional-based analytical cross-sectional study was conducted from March to July 2020 using 48 paired plasma and DBS samples among people living with HIV at the HIV Treatment Center, Northwest Ethiopia. A total of four milliliters of venous blood was collected to harvest plasma and for DBS sample preparation. The HIV-1 RNA extraction, amplification, and quantification were performed using the Roche COBAS AmpliPrep/COBAS TaqMan version 2.0 assay. Data were managed and analyzed using SPSS version 26 software. Mean HIV-1 viral load measurements as well as the associations between plasma and DBS sample measurements were computed using a paired sample t-test and Pearson's correlation statistical tests, respectively. In addition, the level of agreement and the presence of proportional bias between sample measurements were performed using the Bland-Altman plot and linear regression models, respectively. A p-value of ≤ 0.05 with a 95% confidence interval was considered statistically significant.
resultsAmong 48 people living with HIV, more than half (64.6%) of them were females. The minimum and maximum age of the study participants was 12 and 58 years, respectively. The mean difference with standard deviation (SD) of sample measurements (DBS minus plasma) HIV-1 viral load was 0.66 ± 0.70 log copies/mL. In the current study, a strong association with a significant linear correlation (r = 0.796) (p < 0.001) was obtained from Pearson's correlation analysis among HIV-1 viral load measurements between DBS and plasma samples. Moreover, the Bland-Altman plot also depicted a high level of agreement between the sample measurements.
conclusionsThe findings of the current study suggested that DBS samples could be considered as an alternative approach for periodic monitoring of HIV-1 viral loads to scale-up the HIV diagnosis and treatment coverage, particularly in areas with limited laboratory settings due to minimal invasive blood collection, higher stability at room temperature or ease of transportation, and decentralized sample collection approaches.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.