Evidence map›Paper›PMID 40375182›Full record

ArticleBMC musculoskeletal disorders2025

Biomechanical properties of off-axis screw in the treatment of vertical femoral neck fractures: a finite element analysis.

Yimiao Lin, Fengting Cui, Zhaofeng Jia, Xinjia Hu, Shiyuan Lin

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yimiao Lin *Department of Trauma Orthopedic, Shenzhen People's Hospital, The Second Clinical, Medical College of Jinan University and The First Affiliated Hospital of Southern University of Science and Technology, No. 1017 Dongmen North Road, Luohu District, Shenzhen, Guangdong, 518035, China.
Fengting Cui *Department of Trauma Orthopedic, Shenzhen People's Hospital, The Second Clinical, Medical College of Jinan University and The First Affiliated Hospital of Southern University of Science and Technology, No. 1017 Dongmen North Road, Luohu District, Shenzhen, Guangdong, 518035, China.
Zhaofeng Jia *Department of Trauma Orthopedic, Shenzhen People's Hospital, The Second Clinical, Medical College of Jinan University and The First Affiliated Hospital of Southern University of Science and Technology, No. 1017 Dongmen North Road, Luohu District, Shenzhen, Guangdong, 518035, China.
Xinjia HuDepartment of Trauma Orthopedic, Shenzhen People's Hospital, The Second Clinical, Medical College of Jinan University and The First Affiliated Hospital of Southern University of Science and Technology, No. 1017 Dongmen North Road, Luohu District, Shenzhen, Guangdong, 518035, China. hxjys888@hotmail.com.
Shiyuan LinDepartment of Trauma Orthopedic, Shenzhen People's Hospital, The Second Clinical, Medical College of Jinan University and The First Affiliated Hospital of Southern University of Science and Technology, No. 1017 Dongmen North Road, Luohu District, Shenzhen, Guangdong, 518035, China. lin2019214@163.com.

Funding

Shenzhen Science and Technology Projects JCYJ20220530152213030Shenzhen Science and Technology Projects JCYJ20220530152214032
6 · The paper itself

Abstract

purposeThis study aims to assess the biomechanical performance of the 7.3 mm fully threaded off-axis screw (7.3-FTOS) configuration in stabilizing vertical femoral neck fractures (FNSs), comparing its effectiveness with other fixation methods.

methodsA vertical FNF model with an 80° Pauwels angle was simulated and stabilized using four internal fixation constructs: Three inverted cannulated compression screws (ICCS), 7.3 mm partially threaded off-axis screw (7.3-PTOS), 4.5 mm fully threaded off-axis screw (4.5-FTOS), and 7.3-FTOS. The fracture fixation models were developed, refined, and optimized using Geomagic for 3D reconstruction and surface smoothing, and SolidWorks for parametric modeling. Comparative finite element analysis was then conducted using Ansys to assess the biomechanical behavior of each fixation method.

resultsThe maximum femoral displacements for ICCS, 7.3-PTOS, 4.5-FTOS and 7.3-FTOS were 10.40 mm, 8.08 mm, 7.71 mm, and 7.15 mm, respectively. The peak internal fixation displacements were 9.76 mm, 7.55 mm, 7.25 mm, and 6.78 mm, respectively. The maximum gap displacement measured 2.73 mm, 1.19 mm, 0.94 mm, and 0.55 mm, respectively. The maximum displacement along the Z-axis, representing the shear force direction, was recorded as 2.93 mm, 2.69 mm, 2.66 mm, and 2.63 mm, respectively. The peak von Mises stress (VMS) values in the distal femur were 218.04 MPa, 121.99 MPa, 123.42 MPa, and 113.86 MPa, respectively. The peak VMS values of the internal fixation constructs were 10.40 mm, 8.08 mm, 7.71 mm, and 7.15 mm, respectively.

conclusionsFinite element analysis results revealed that 7.3-FTOS configuration exhibited superior resistance to shear and rotational forces in vertical FNFs compared to ICCS, 7.3-PTOS, and 4.5-FTOS, demonstrating enhanced mechanical performance. These findings establish a foundation for advancing experimental investigations and potential future clinical translation.

Indexed as

Bone ScrewsFemoral Neck FracturesFinite Element AnalysisFracture Fixation, InternalBiomechanical PhenomenaHumansFinite element analysisOff-axis screwVertical femoral neck fracture

Identifiers

PMID40375182
PMCPMC12080130

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.