ArticleJMIR rehabilitation and assistive technologies2025
Validation of Gait Kinematics With Ramp and Stair Ascent and Descent Revealed by Markerless Motion Capture in Simulated Living Space: Test-Retest Reliability Study.
Article in JMIR rehabilitation and assistive technologies, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Age-Related Differences in Joint Kinematics and Spatiotemporal Parameters During Ramp Walking and Level Walking: Cross-Sectional Study.JMIR biomedical engineering · 2026Article
- Enhancing Self-Efficacy Through Robotic Safety Support in Balance-Challenging Reach Tasks: Feasibility Study in Young Adults.JMIR rehabilitation and assistive technologies · 2025Article
- High-Accuracy Lower-Limb Intent Recognition: A KPCA-ISSA-SVM Approach with sEMG-IMU Sensor Fusion.Biomimetics (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: In recent years, there has been an increasing demand for markerless motion capture systems, which are being widely used in biomechanical and clinical research. Furthermore, by using a markerless motion capture system in a laboratory environment that mimics living spaces, the data acquired on various activities of daily living, such as level walking, ramp walking, and stair ascent and descent, should more closely resemble that of real-life activities. However, the absolute reliability of gait parameters in this context is still unclear. Objective: The aim of this study was to evaluate the reliability of a markerless motion capture system in assessing the ascent and descent of ramps and stairs during walking in a simulated living space. Methods: A total of 21 healthy participants performed level walking, ramp and stair ascent and descent on two separate days, with at least a 24-hour interval between sessions. Joint angles were measured using 27 synchronized cameras with a markerless motion capture application, Theia3D (Theia Markerless Inc), and analyzed in Visual3d for all planes of motion at the hip-, knee-, and ankle-joints. The absolute reliability of day-to-day reproducibility was assessed using full-curve analysis (root mean square difference [RMSD]) and discrete point analysis of gait events using the standard error of measurement (SEM). SEM was calculated only for level walking and ramp ascent and descent, where gait events were correctly detected. Results: The SEM values for level walking and ramp ascent and descent were all below the 5-degree threshold. However, while RMSD values were generally below 5°, this threshold was exceeded for knee-joint flexion-extension angles during ramp ascent and stair ascent (5.07° and 5.64°, respectively). Conclusions: The markerless motion capture system in the living laboratory setting demonstrated a high degree of accuracy for various environments and gait types. The low SEM values obtained indicate good reliability for joint angle measurements across different days. The slightly higher RMSD values for knee-joint angles during ramp and stair ascent may reflect the system's ability to capture the adaptations in joint kinematics in response to changes in gait conditions. These measurements in a living laboratory environment validated the absolute reliability of various gait parameters not only in level walking but also in ramp and stair ascent and descent. The findings suggest potential clinical applications and research opportunities, including the development of assistive devices and robots, using markerless motion capture in more natural living situations, rather than in controlled environments.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.